نتایج جستجو برای: treatment dose correction

تعداد نتایج: 1752083  

2014
Yuichi Akino Indra J. Das Higinia R. Cardenes Colleen M. Desrosiers

Recently, stereotactic body radiotherapy (SBRT) for lung cancer is conducted with heterogeneity-corrected treatment plans, as the correction greatly affects the dose delivery to the lung tumor. In this study, the correlation between the planning target volume (PTV) and the dose delivery is investigated by separation of the heterogeneity correction effects into photon attenuation and electron tr...

Journal: :International journal of radiation oncology, biology, physics 2012
Gavin G Poludniowski Philip M Evans Steve Webb

PURPOSE The potential of keV cone beam computed tomography (CBCT) for guiding adaptive replanning is well-known. There are impediments to this, one being CBCT number accuracy. The purpose of this study was to investigate CBCT number correction methods and the affect of residual inaccuracies on dose deposition. Four different correction strategies were applied to the same patient data to compare...

2012
Masaru Narabayashi Takashi Mizowaki Yukinori Matsuo Mitsuhiro Nakamura Kenji Takayama Yoshiki Norihisa Katsuyuki Sakanaka Masahiro Hiraoka

Heterogeneity correction algorithms can have a large impact on the dose distributions of stereotactic body radiation therapy (SBRT) for lung tumors. Treatment plans of 20 patients who underwent SBRT for lung tumors with the prescribed dose of 48 Gy in four fractions at the isocenter were reviewed retrospectively and recalculated with different heterogeneity correction algorithms: the pencil bea...

B.M. Park, B.O. Choi, B.Y. Choe, J.B. Chung, J.W. Lee, J.Y. Jung, T.S. Suh, Y.J. Shin, Y.K. Bae, Y.L. Kim,

Background: Dose calculation algorithms play a very important role in predicting the explicit dose distribution. We evaluated the percent depth dose (PDD), lateral depth dose profile, and surface dose volume histogram in inhomogeneous media using calculation algorithms and inhomogeneity correction methods. Materials and Methods: The homogeneous and inhomogeneous virtual slab phantoms used in th...

2012
CW Kong SK Yu KY Cheung H Geng YW Ho WW Lam WK Wong

PURPOSE To evaluate the performance of 2D-array I'mRT MatriXX for dose verification of TomoDirect treatment plans. METHODS In this study, a 2D-array ion chamber device - the I'mRT MatriXX and Multicube Phantom from IBA - was used for dose verification of different TomoDirect plans. Pre-treatment megavoltage computed tomography (MVCT) was performed on the phantom setup for position correction....

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه ارومیه - دانشکده ادبیات و علوم انسانی 1390

the present study was concerned with exploring the frequency and linguistic focus of corrective feedback types given by novice and experienced female teachers working with young learners and compared it with those of elementary classes for adults. moreover, it aimed at measuring learners’ acknowledgement of teachers’ corrective feedback in the form of uptake in relation to linguistic coverage o...

2016
Alireza Mohammadkarim Hasan Ali Nedaie Mahmoud Allahverdi Mahbod Esfehani Alireza Shirazi Ghazale Geraily

Introduction Evaluation of the delivered dose of externally wedged photon beams by external diode dosimeters during the treatment process requires the estimation of exit surface dose correction factors in various wedge angles

2009
Jean‐François Aubry Joey Cheung Olivier Morin Alexander Gottschalk Luc Beaulieu Jean Pouliot

Megavoltage cone-beam CT (MVCBCT) is an imaging technology that provides a 3D representation of the patient in treatment position. Because it is a form of x-ray tomography, MVCBCT images give information about the attenuation coefficients of the imaged tissues, and thus could be used for dose calculation. However, the cupping and missing data artifacts seen on MVCBCT images can cause inaccuraci...

2013
Jiazhou Wang Weigang Hu Gang Cai Jiayuan Peng Ziqiang Pan Xiaomao Guo Jiayi Chen

BACKGROUND Accurate target localization is mandatory in the accelerated partial breast irradiation (APBI) delivery. Dosimetric verification for positional error will further guarantee the accuracy of treatment delivery. The purpose of this study is to evaluate the clinical feasibility of a cone beam computer tomographic (CBCT) image correction method in APBI. METHODS A CBCT image correction m...

Journal: :iranian journal of radiation research 0
m. akram department of physics, the islamia university of bahawalpur pakistan k. iqbal department of physics, the islamia university of bahawalpur pakistan m. isa department of physics, the islamia university of bahawalpur pakistan m. afzal department of physics, the islamia university of bahawalpur pakistan s.a. buzdar department of physics, the islamia university of bahawalpur pakistan

background: it was intended to investigate the effect of physical wedge (pw) and enhanced dynamic wedges (edw) on contralateral breast dose during primary breast irradiation in radiotherapy treatment, using high energy photon beams. materials and methods: the varian’s clinac dual mode linear accelerator model 2100 c/d and siemen’s primus accelerators were used for radiation doses with 6 mv and ...