نتایج جستجو برای: ultrasonic c scan

تعداد نتایج: 1156263  

Journal: :Dental materials journal 2007
Kyou Hiasa Yasuhiko Abe Yasuhiro Yoshida Tsuyoshi Taji Kazuomi Suzuki Yasumasa Akagawa

The purpose of this study was to investigate the chemical interaction between titanium implant surface and amino acids. Pure titanium disks were pretreated with 10 N HCl and ultrapure water at room temperature for 30 minutes each. Disks were then modified with one of the three amino acids--L-aspartic acid, L-serine, or L-threonine--at 37 degrees C for 12 hours. Modification with oxalic acid was...

2011
Kyle Hoegh Thomas Yu

Ultrasonic tomography is an emerging technology that shows promise for quality assurance/quality control (QA/QC) during construction, or for making rehabilitation decisions in concrete pavements. However, the benefits of this emerging technology have not yet been fully captured for widespread use in highway infrastructure management. Verification of a state-of-the-art ultrasonic tomography devi...

2008
Zhenggan ZHOU Zhanying FENG

Ultrasonic guided wave can propagate over a long distance and can be used to inspect plate and shell structure. Line-scan method is always applied to guide wave inspection. However, it is a problem how to locate the defects and how to image the inspection results if the through transmission method is used. In order to solve this problem, the imaging method of inspection results with ultrasonic ...

2015
Serdar Aktas Hatice Aktas Mehmet Tetikoglu Hacı Murat Sagdık Fatih Özcura Patrick Wall.

The aim of the study was to compare the measurements of optical (AL-Scan; Nidek Co., Ltd.) and ultrasonic (Echo Scan US-800; Nidek Co., Ltd.) biometry devices and to assess refractive results after cataract surgery. Eighty-one cataractous eyes of 81 patients were included in this study. Biometry was performed using the AL-Scan and an ultrasonic biometer (USB). Axial length (AL), keratometry (K)...

Journal: :journal of agricultural science and technology 2015
b. hosseinzadeh samani m. h. khoshtaghaza s. minaee s. abbasi

this study aimed to examine the effectiveness of combined microwave-ultrasonic pasteurization system on escherichia coli and vitamin c content in sour cherry juice (scj). based on the findings, microwave output power, ultrasound power, and ultrasonic exposure time as well as the microwave-induced temperature were the most effective factors in reducing e. coli and vitamin c content. in addition,...

2016
Xueping JIANG Qingbang HAN Hui ZHENG Guoliang TIAN Peng WANG

Phased array ultrasonic testing technology is of flexible, reliable, efficient and suitable for special equipment welds non-destructive testing. Sectorial scan angle range was investigated in this paper for phased array ultrasonic oblique incident pulse shear wave testing of special equipment welds made in low carbon steel. The theoretical calculation of ultrasound wave energy transmission coef...

Journal: :Medical physics 2000
G Ku L V Wang

Microwave-induced thermoacoustic tomography was explored to image biological tissue. Short microwave pulses irradiated tissue to generate acoustic waves by thermoelastic expansion. The microwave-induced thermoacoustic waves were detected with a focused ultrasonic transducer. Each time-domain signal from the ultrasonic transducer represented a one-dimensional image along the acoustic axis of the...

Journal: :Bio-medical materials and engineering 2015
Xiaonian He Weixiang Liu Siping Chen Zhengdi Qin

In the field of ultrasonic imaging technology, the problem of geometric distortion is often encountered, especially in the ultrasonic near-field. In this study, a new approach is proposed to compensate for geometric distortion in the synthetic aperture ultrasonic imaging system. This approach is based on the synthetic aperture ultrasonic holographic B-scan (UHB) imaging system, which is a combi...

2017
Tai Chieh Wu Makiko Kobayashi Masayuki Tanabe Che-Hua Yang

In this study, a flexible ultrasonic transducer (FUT) was applied in a laser ultrasonic technique (LUT) for non-destructive characterization of metallic pipes at high temperatures of up to 176 °C. Compared with normal ultrasound transducers, a FUT is a piezoelectric film made of a PZT/PZT sol-gel composite which has advantages due to its high sensitivity, curved surface adaptability and high te...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید