نتایج جستجو برای: ventilation tube

تعداد نتایج: 141661  

Journal: :Archives of disease in childhood. Fetal and neonatal edition 2004
C H Cole J P Mitchell M P Foley M W Nagel

Dose delivery of hydrofluoroalkane-beclomethasone and chlorofluorocarbon-beclomethasone was compared during in vitro neonatal simulations: mechanical ventilation with 40% and 100% relative humidity + Neonatal Chamber-Ventilator System/endotracheal tube; manual ventilation + Neonatal Chamber/endotracheal tube; "spontaneous breathing" + Neonatal Chamber/face mask without/with manual assistance. T...

Journal: :American journal of respiratory and critical care medicine 1997
A Esteban I Alía F Gordo R Fernández J F Solsona I Vallverdú S Macías J M Allegue J Blanco D Carriedo M León M A de la Cal F Taboada J Gonzalez de Velasco E Palazón F Carrizosa R Tomás J Suarez R S Goldwasser

A 2-h T-tube trial of spontaneous breathing was used in selecting patients ready for extubation and discontinuation of mechanical ventilation. However, some doubt remains as to whether it is the most appropriate method of performing a spontaneous breathing trial. We carried out a prospective, randomized, multicenter study involving patients who had received mechanical ventilation for more than ...

Journal: :The American journal of emergency medicine 1985
C F Babbs W E Schoenlein M W Lowe

This study was undertaken to determine the effect of interposed abdominal compressions (IAC) during cardiopulmonary resuscitation (CPR) on gastric insufflation when the airway is not secured with an endotracheal tube. A canine model was used in which a common ventilation pressure was applied to separate cuffed esophageal and tracheal tubes. Gas entering the stomach was collected by a pre-placed...

Journal: :Medicina intensiva 2013
F Frutos-Vivar A Esteban

Most patients who require mechanical ventilation for longer than 24 hours, and who improve the condition leading to the indication of ventilatory support, can be weaned after passing a first spontaneous breathing test. The challenge is to improve the weaning of patients who fail that first test. We have methods that can be referred to as traditional, such as the T-tube, pressure support or sync...

2015
Jae Hee Woo Rack Kyung Chung Hee Jung Baik Youn Jin Kim

We present a case of an alveolar-pleural fistula with hepatic hydrothorax in a patient undergoing orthotropic liver transplantation, which was detected by drainage of transudate through an endotracheal tube during operation. A standard endotracheal tube was changed to a double-lumen tube to provide differential lung ventilation. The patient was diagnosed with an alveolar-pleural fistula by dire...

Journal: :Croatian medical journal 2004
Ivo Matić Visnja Majerić-Kogler

AIM To compare T-tube and pressure support ventilation (PSV) as two methods of weaning patients from mechanical ventilation. METHODS A randomized prospective study included 260 patients who received mechanical ventilation for more than 48 h, and who were admitted to the intensive care unit (ICU) at Dr. Josip Bencevic General Hospital in Slavonski Brod, between August 1999 and October 2000. Af...

Journal: :evidence based care 0
javad malekzadeh evidence based care research centre, instructor of nursing, instructor of medical-surgical nursing, school of nursing and midwifery, mashhad university of medical sciences, mashhad, iran mahboube yazdani ms in nursing, school of nursing and midwifery, mashhad university of medical sciences, mashhad, iran alireza sedaghat associate professor of anesthesiology and critical care, school of medicine, mashhad university of medical sciences, mashhad, iran seyed reza mazlom evidence based care research centre, instructor of nursing, instructor of medical-surgical nursing, school of nursing and midwifery, mashhad university of medical sciences, mashhad, iran

background: postoperative pulmonary complications (ppc) are of the major reasons for death. prolonged mechanical ventilation (pmv) and delayed extubation are leading to the incidence of more seriously complications. the effect of hyperinflation has not been investigated in control of these complications in patients who have been weaned from mechanical ventilation and are undergoing t-tube suppo...

Journal: :Archives of Otolaryngology–Head & Neck Surgery 1999

Journal: :Sri Lankan Journal of Anaesthesiology 2014

Journal: :The European respiratory journal 1999
C Feldman M Kassel J Cantrell S Kaka R Morar A Goolam Mahomed J I Philips

Endotracheal tube colonization in patients undergoing mechanical ventilation was investigated. In the first part of this prospective study, the airway access tube was examined for the presence of secretions, airway obstruction and bacterial colonization, in cases undergoing extubation or tube change. In the second part of the study, the sequence of oropharyngeal, gastric, respiratory tract and ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید