نتایج جستجو برای: voxelized phantom

تعداد نتایج: 17420  

2003
John J. DeMarco Timothy D. Solberg Nzhde Agazaryan

We describe a method for independently verifying the dose distributions from pre- and post-implant brachytherapy source distributions. Monte Carlo calculations have been performed to characterize the three-dimensional dose distribution in water phantom from a low-energy brachytherapy source. The calculations are performed in a voxelized, Cartesian coordinate geometry and normalized based upon a...

Journal: :Physics in medicine and biology 2009
Niklas S Rehfeld Simon Stute John Apostolakis Marine Soret Irène Buvat

Geant4 Application for Emission Tomography (GATE) is a widely used, well-validated and very versatile application for Monte Carlo simulations in emission tomography. However, its computational performance is poor, especially for voxelized phantoms, partly due to the use of a very general particle tracking algorithm. In this work, two methods are proposed to reduce the time spent on particle tra...

2013
Kyung-Kyu Kang Dongho Kim

We present a real-time subsurface scattering simulation to perform real-time rendering of translucent particle-based fluids. After particle-based fluid simulation, we immediately build voxelized fluids, called Voronoi fluids, with particle locations and neighbour lists using GPUs. And then, we perform a multiple subsurface scattering simulation over the Voronoi fluids with the diffusion equatio...

2008
Elmar Eisemann Xavier Décoret

In this paper, we present a single-pass technique to voxelize the interior of watertight 3D models with high resolution grids in realtime during a single rendering pass. Further, we develop a filtering algorithm to build a density estimate that allows the deduction of normals from the voxelized model. This is achieved via a dense packing of information using bitwise arithmetic. We demonstrate t...

Journal: :iranian journal of radiation research 0
s. senthilkumar department of radiotherapy, madurai medical college and govt. rajaji hospital, maduari-625 020, india

background: the purpose of this study is to fabricate inexpensive in-house low cost homogeneous and heterogeneous human equivalent thorax phantom and assess the dose accuracy of the treatment planning systems (tps) calculated values for different lung treatment dosimetery. it is compared with thermoluminescent dosimeter (tld) measurement. materials and methods: homogeneous and heterogeneous tho...

Journal: :IEEE Sensors Journal 2023

Point cloud compression is an essential task for practical applications using point clouds. Most of the previous approaches rely on octree which involves voxelization in coding itself. Distortions derived from can be reduced without increasing bitrate by postprocessing. In this article, we propose a super-resolution method decoded voxelized as postprocessing step geometry compression. The propo...

Journal: :iranian journal of radiation research 0
j.w. hong department of radiation oncology, seoul national university bundang hospital, republic of korea h.k. lee department of computer science and engineering, soonchunhyang university, republic of korea j.h. cho department of international radiological science, hallym university of graduate studies, republic of korea

background: this study assessed the clinical usefulness of the solid phantom, which may compensate for the disadvantages of the water phantom, by comparing the radiological doses between the two depending on their depths. materials and methods: the experimental equipment used was a linear accelerator for medical use, water phantom, solid phantom, farmer type ion chamber and electrometer. the di...

Jalil Pirayesh Islamian, Parvaneh Darkhor Samira Abbaspour

Introduction: In nuclear medicine, the use of a pixelated semiconductor detector such as CZT is an of growing interest for introducing new devices. Especially, the spatial resolution can be improved by using a pixelated parallel-hole collimator with equal holes and pixel sizes based on the pixelated detector. The purpose of this study was to compare the effect of pixelated and ...

Journal: :iranian journal of child neurology 0
mahtab poor zamany nejat kermany 1. anesthesiology and critical care deprtment, labbafinejad hospital, medical university of shahid beheshti, tehran, iran ehsan modirian 2. emergency medicine department, boali hospital, qazvin university of medical sciences, qazvin, iran mohammadreza soroush 3. janbazan medical and engineering research center (jmerc), tehran, iran mahdi masoumi 3. janbazan medical and engineering research center (jmerc), tehran, iran maryam hosseini 3. janbazan medical and engineering research center (jmerc), tehran, iran

how to cite this article: poor zamany nejat kermany m, modirian e, soroush m, masoumi m, hosseini m. phantom limb sensation (pls) and phantom limb pain (plp) among young landmine amputees. iran j child neurol. summer 2016; 10(3):42-47.   abstract objective to determine the frequency of phantom limb sensation (pls) and phantom limb pain (plp) in children and young adults suffering landmine-relat...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید