نتایج جستجو برای: مدل ldf

تعداد نتایج: 120467  

Journal: :Physics in medicine and biology 2009
Tiziano Binzoni Terence S Leung Dimitri Van De Ville

Monte Carlo (MC) simulations significantly contributed to a better understanding of laser-Doppler flowmetry (LDF). Here it is shown that the data obtained from standard MC simulations can be reinterpreted and used to extract more information such as the photo-electric current (i(t)). This is important because i(t) is the starting point for evaluating any existing or new algorithm to be used in ...

Journal: :Journal of biomedical optics 2013
Martial H Geiser Frederic Truffer Hugo Evequoz Hafid Khayi Benjamin Mottet Christophe Chiquet

We describe a device to measure blood perfusion for the human optic nerve head (ONH) based on laser Doppler flowmetry (LDF) with a flicker stimuli of the fovea region. This device is self-aligned for LDF measurements and includes near-infrared pupil observation, green illumination, and observation of the ONH. The optical system of the flowmeter is based on a Schlieren arrangement which collects...

Journal: :Journal of neurology, neurosurgery, and psychiatry 1994
P J Kirkpatrick P Smielewski M Czosnyka J D Pickard

A method for monitoring cortical perfusion by laser Doppler flowmetry (LDF) in the neurointensive care unit is described. Out of 22 patients with head injuries, reliable and long term recordings were obtained in 16. Laser Doppler flowmetry registered changes in cortical microcirculatory flow in response to spontaneous waves of raised intracranial pressure, and to therapeutic manoeuvres that alt...

Journal: :Journal of endodontics 2011
Eugene Chen Paul V Abbott

INTRODUCTION The aim of this study was to compare the clinical accuracy, reliability, and repeatability of laser Doppler flowmetry (LDF), an electric pulp test (EPT), and various thermal pulp sensibility tests. METHODS Pulp tests were done on 121 teeth in 20 subjects by using LDF, EPT, and thermal pulp testing (CO(2), Endo Frost [EF], Ice) during 2 or 3 test sessions with at least 1-week inte...

2014
Jeremiah K. H. Lim Christine T. O. Nguyen Zheng He Algis J. Vingrys Bang V. Bui

PURPOSE To investigate the effect of ageing on the recovery of ocular blood flow, intravitreal oxygen tension and retinal function during and after intraocular pressure (IOP) elevation. METHODS Long Evans rats (3- and 14-month-old) underwent acute stepwise IOP elevation from 10 to 120 mmHg (5 mmHg steps each 3 minutes). IOP was then returned to baseline and recovery was monitored for 2 hours....

Journal: :Blood 2000
V Shetty S Hussaini L Broady-Robinson K Allampallam S Mundle R Borok E Broderick L Mazzoran F Zorat A Raza

A higher percentage of apoptotic cells (apoptotic index or AI) is consistently found in bone marrow (BM) biopsies compared to BM aspirates of patients with myelodysplastic syndrome (MDS). Most studies have only investigated the low-density fraction (LDF) mononuclear cells from BM aspirates following density separation for AI determination. In the present study, both LDF and high-density fractio...

2001
Chin-Hwa Kuo David Wible Chih-Chiang Wang Feng-yi Chien

In this paper, we describe the design and implementation of a tool called the Lexical Difficulty Filter (LDF) intended to help learners or teachers in selecting sentences appropriate to the level of students for English vocabulary learning. The LDF serves as a bridge between learner and information resource bank. It selects suitable sentences from the output of standard English corpus concordan...

Journal: :Applied optics 2014
Tiziano Binzoni Dimitri Van De Ville Bruno Sanguinetti

A new laser-Doppler flowmeter at large interoptode spacing, based on single-photon counting (single-photon laser-Doppler flowmetry [SP-LDF]) and allowing assessment of blood flow deep in bone tissue, is proposed and implemented. To exploit the advantages of the new SP-LDF hardware, a dedicated simple and efficient time-domain algorithm has been developed. The new algorithm is based on the zero-...

Journal: :American journal on intellectual and developmental disabilities 2014
Paul Yoder Tiffany Woynaroski Marc Fey Steven Warren

Children with intellectual disability were randomly assigned to receive Milieu Communication Teaching (MCT) at one 1-hr session per week (low dose frequency, LDF) or five 1-hr sessions per week (high dose frequency, HDF) over 9 months ( Fey, Yoder, Warren, & Bredin-Oja, 2013 . Non-Down syndrome (NDS) and Down syndrome (DS) subgroups were matched on intelligence, mental age, and chronological ag...

2015
Shuichi Shinmura

In this paper, we focus on the new model selection procedure of the discriminant analysis. Combining resampling technique with k-fold cross validation, we develop a k-fold cross validation for small sample method. By this breakthrough, we obtain the mean error rate in the validation samples (M2) and the 95% confidence interval (CI) of discriminant coefficient. Moreover, we propose the model sel...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید