Journal: :Medical physics 2006
Ali S Meigooni Shahid B Awan Kai Dou

Recently, elongated brachytherapy sources (active length >1 cm) have become commercially available for interstitial prostate implants. These sources were introduced to improve the quality of brachytherapy procedures by eliminating the migration and seed bunching associated with loose seed-type implants. However, the inability to calibrate elongated brachytherapy sources with the Wide-Angle Free...

Mojtaba Shamsaei Zafarghandi Seyed Milad Vahabi,

Introduction Dose calculation of tumor and surrounding tissues is essential during prostate brachytherapy. Three radioisotopes, namely, 125I, 103Pd, and 131Cs, are extensively used in this method. In this study, we aimed to calculate the received doses by the prostate and critical organs using the aforementioned radioactive seeds and to investigate the effect of scattering contribution for the ...

Introduction: 103Pd is a low energy source, which is used in brachytherapy. According to the standards of American Association of Physicists in Medicine, dosimetric parameters determination of brachytherapy sources before the clinical application was considered significantly important. Therfore, the present study aimed to compare the dosimetric parameters of the target source using the water ph...

Journal: :Medical physics 2011
Mark J Rivard Sou-Tung Chiu-Tsao Paul T Finger Ali S Meigooni Christopher S Melhus Firas Mourtada Mary E Napolitano D W O Rogers Rowan M Thomson Ravinder Nath

PURPOSE To investigate dosimetric differences among several clinical treatment planning systems (TPS) and Monte Carlo (MC) codes for brachytherapy of intraocular tumors using 125I or 103Pd plaques, and to evaluate the impact on the prescription dose of the adoption of MC codes and certain versions of a TPS (Plaque Simulator with optional modules). METHODS Three clinical brachytherapy TPS capa...

Journal: :iranian journal of medical physics 0
seyed milad vahabi energy engineering and physics department, amirkabir university of technology, tehran, iran mojtaba shamsaei zafarghandi energy engineering and physics department, amirkabir university of technology, tehran, iran

introduction dose calculation of tumor and surrounding tissues is essential during prostate brachytherapy. three radioisotopes, namely, 125i, 103pd, and 131cs, are extensively used in this method. in this study, we aimed to calculate the received doses by the prostate and critical organs using the aforementioned radioactive seeds and to investigate the effect of scattering contribution for the ...