1997
Y C Cheung Peter K N Yu E C M Young C L Chan M F Ng Francis Tang

A Monte Carlo simulation using the PRESTA version of the EGS4 code has been employed as an investigative tool to calculate the absorbed dose in water close to 192Ir wire implants. It has been shown that a treatment planning system, such as GE Target II, using the Sievert integral and the Meisberger polynomial is only able to reproduce the Monte Carlo results at radial distances of 1 mm and fart...

Abdolazim Sedighi Fahimeh Rezaei, Mohammad Hadi Gholami Mohammad Mohammadi, Ramin Jaberi

Introduction: A study was performed to evaluate radiation dose distribution and dose gradient around cylindrical applicators for high-dose-rate (HDR) brachytherapy systems with 192Ir, 60Co brachytherapy source applied for rectal and vaginal cancers treatments.   Materials and Methods: Two additional computed tomography (CT) based plans were generated using a ...

2013
Mehdi Zehtabian Sedigheh Sina Reza Faghihi Ali Meigooni

In the recommendations of Task Group #43 from American Association of Physicists in Medicine (AAPM TG43), methods of brachytherapy source dosimetry are recommended, under full scattering conditions. However, in actual brachytherapy procedures, sources may not be surrounded by full scattering tissue in all directions. Clinical examples include high-dose-rate (HDR) brachytherapy of the breast or ...

ژورنال: سنجش و ایمنی پرتو 2017

Radioactive 125I and 192Ir seeds are widely used as sources for interstitial implantation.192Ir is one of the important sources frequently used in brachytherapy. Up to now, different commercial models of this source type have been introduced to the clinical radiation oncology applications. The aim of the present study is to determine the dosimetric parameters of this new PDR Ir-192 source model...

Journal: :Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine 2006
W M Van Wyngaardt B R S Simpson

Four radionuclides with electron-capture-based decay schemes have been directly measured by a liquid scintillation coincidence extrapolation technique. 125I, 192Ir and 65Zn were measured as part of international key comparisons held under the auspices of the International Bureau of Weights and Measures (BIPM). The 139Ce measurements formed part of a regional comparison organized by the Asia Pac...