نتایج جستجو برای: 3d dosimetry

تعداد نتایج: 196009  

Journal: :Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention 2007
Ameet K. Jain Anton Deguet Iulian Iordachita Gouthami Chintalapani J. Blevins Y. Le E. Armour Everette Clif Burdette Danny Y. Song Gabor Fichtinger

Intra-operative guidance in Transrectal Ultrasound (TRUS) guided prostate brachytherapy requires localization of inserted radioactive seeds relative to the prostate. Seeds were reconstructed using a typical C-arm, and exported to a commercial brachytherapy system for dosimetry analysis. Technical obstacles for 3D reconstruction on a non-isocentric C-arm included pose-dependent C-arm calibration...

Journal: :Journal of Physics: Conference Series 2013

2013
Soléakhéna Ken Laure Vieillevigne Xavier Franceries Luc Simon Caroline Supper Jean-Albert Lotterie Thomas Filleron Vincent Lubrano Isabelle Berry Emmanuelle Cassol Martine Delannes Pierre Celsis Elizabeth Moyal Cohen-Jonathan Anne Laprie

BACKGROUND To integrate 3D MR spectroscopy imaging (MRSI) in the treatment planning system (TPS) for glioblastoma dose painting to guide simultaneous integrated boost (SIB) in intensity-modulated radiation therapy (IMRT). METHODS For sixteen glioblastoma patients, we have simulated three types of dosimetry plans, one conventional plan of 60-Gy in 3D conformational radiotherapy (3D-CRT), one 6...

2017
Lucas Persoon

Radiotherapy is one of the main treatment modalities to treat cancer. Image based treatment verification has been recently introduced. However, a quantitative comparison between the planned and delivered dose is a novel development in the field of radiotherapy. In this thesis, the added value of quantitative in-treatment dose measurements techniques to facilitate adaptive radiotherapy has been ...

Journal: :Medical physics 2000
D A Rajon D W Jokisch P W Patton A P Shah W E Bolch

An important problem in internal dosimetry is the assessment of energy deposition by beta particles within trabecular regions of the skeleton. Recent dosimetry methods for trabecular bone are based on Monte Carlo particle transport simulations within three-dimensional (3D) images of real human bone samples. Nuclear magnetic resonance (NMR) microscopy is a 3D imaging technique of choice due to t...

2015
Csaba Pinter Andras Lasso An Wang Gregory C. Sharp Kevin Alexander David Jaffray Gabor Fichtinger

Radiation therapy (RT) is a common treatment option for a wide variety of cancer types. Despite significant improvements in this technique over the past years, software tools for research in RT are limited to either expensive, closed, proprietary applications or heterogeneous sets of open-source software packages with limited scope, reliability, and user support. Our SlicerRT toolkit aspires to...

2014
Mohammad Bakhtiari Ashkan Parniani Fritz Lerma Shannon Reynolds James Jordan Alireza Sedaghat Mehrdad Sarfaraz James Rodgers

BACKGROUND Intensity modulated radiation therapy (IMRT) dosimetry verification is routinely conducted via integrated or individual field dosimetry using film or a matrix of detectors. Techniques and software systems are commercially available which use individual field dosimetry measurements as input into algorithms that estimate 3D patient dose distributions on CT scan derived target volumes a...

2016
Kurtis Dekker Jerry Battista Kevin Jordan

Introduction: Optical CT scanning of radiochromic gel dosimeters is a method for true 3D dosimetry, which is becoming increasingly needed as radiation therapy techniques become more advanced. Optical CT has developed from slow pencil beam laser scanners to fast cone-beam scanners using cameras. However, scattered light perturbs these broad-beam scanners, resulting in cupping artifacts and loss ...

ژورنال: سنجش و ایمنی پرتو 2016

The object of this research is the investigation of carbon nanotube (CNT) distribution effect on electrical conductivity of polymer-CNT composite as dosimetry response of this system. Thus, electrical conductivity of this composite was simulated for aligned, homogenous, and agglomerated distributions in 2D, and 3D situations. The results of simulation were compared and validated by experimental...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید