نتایج جستجو برای: aami standard

تعداد نتایج: 517223  

Journal: :JAPANES JOURNAL OF MEDICAL INSTRUMENTATION 1987

Journal: :Journal of human hypertension 1991
E O'Brien K O'Malley F Mee N Atkins J Cox

Before the diagnostic potential of 24-hour non-invasive BP measurement can be assessed, the accuracy of ambulatory recorders must be established, and normal reference values determined. The accuracy criteria of four ambulatory BP measuring systems (the SpaceLabs 90207, the Novecor DIASYS 200, the Takeda TM-2420 and the Del Mar Avionics Pressurometer IV) have been assessed according to the Briti...

Journal: :Blood pressure monitoring 2000
E O'Brien

Correspondence to Professor Eoin O’Brien, The Blood Pressure Unit, Beaumont Hospital, Dublin 9, Ireland. Tel : +353 1 809 21qO; fax: i-353 1 809 3005; e-mail: [email protected] Introduction Experience with the protocols of the British Hypertension Society (BHS) and the Association for the Advancement of Medical Instrumentation (AAMI) has provided valuable insight into the methodological problems a...

Journal: :Computer Methods and Programs in Biomedicine 2021

Background and objectives: Continuous non-invasive blood pressure monitoring would revolutionize healthcare. Currently, (BP) can only be accurately monitored using obtrusive cuff-based devices or invasive intra-arterial monitoring. In this work, we propose a novel hybrid neural network for the accurate estimation of electrocardiogram (ECG) photoplethysmogram (PPG) waveforms as inputs. Methods: ...

Journal: :Bionatura (Ibarra - Impresa) 2023

The significance of endotoxin-free, sterile dialysis fluid for long-term, high-quality hemodialysis treatment is obvious and highly desired[MF1] . current study aimed to determine endotoxin the water quality used in twenty centers. Eighty samples (40 x dialysates 40 water) were tested using LAL gel clot method. results revealed a variation produced that makes it unaccepted compared internationa...

2012
Sung Chuang

METHodS The CBP monitor provided readings of brachial systolic BP (SBP), brachial diastolic BP (DBP), central SBP, and central pulse pressure (PP). Brachial PP and central DBP were calculated from the relevant readings. The accuracy of the brachial and central SBP, PP, and DBP was validated against the simultaneously recorded invasively measured central aortic SBP, PP, and DBP, according to the...

Journal: :Arquivos brasileiros de cardiologia 2002
Gisele M P Mano Viviane F Souza Angela M G Pierin Josiane C Lima Edna C Ignes Kátia C Ortega Décio Mion

OBJECTIVE To assess the Dixtal DX2710 automated oscillometric device used for blood pressure measurement according to the protocols of the BHS and the AAMI. METHODS Three blood pressure measurements were taken in 94 patients (53 females 15 to 80 years). The measurements were taken randomly by 2 observers trained to measure blood pressure with a mercury column device connected with an automate...

Journal: :Infection control and hospital epidemiology 2015
Amber H Mitchell

1. An overview of central sterile supply department of the Tata Medical Center, Kolkata. In: Scientific Operating Procedures for Sterilization Practices in India. New Delhi: Office of the Principal Scientific Adviser to the Government of India; 2012:165–183. 2. Basu D, Bhattacharya S, Mahajan A, Ramanan VR, Chandy M. The importance of the central sterile supply department in infection preventio...

2017
Irwin Gratz Edward Deal Francis Spitz Martin Baruch I. Elaine Allen Julia E. Seaman Erin Pukenas Smith Jean

BACKGROUND Despite increased interest in non-invasive arterial pressure monitoring, the majority of commercially available technologies have failed to satisfy the limits established for the validation of automatic arterial pressure monitoring by the Association for the Advancement of Medical Instrumentation (AAMI). According to the ANSI/AAMI/ISO 81060-2:2013 standards, the group-average accurac...

Journal: :The journal of extra-corporeal technology 1994
K E Griffith M R Vasquez P D Beckley B J LaLone

Knowledge and predictability of oxygenator performance is vital to safe and effective conduct of cardiopulmonary bypass. The determination of oxygenator performance in the laboratory, however, is carried out under a strict set of conditions established by the Association for the Advancement of Medical Instrumentation (AAMI). This performance data is of limited value in the clinical setting wher...