نتایج جستجو برای: anterior capsular rupture

تعداد نتایج: 170911  

2015
Yuan Zeng Jian-hua Gao

We modified a 2-bend cystotome for continuous curvilinear capsulorhexis (CCC) in manual or phacoemulsification cataract surgery to improve the safety and ease of performance. A 26G needle was converted into a cystotome with 3 bends. In this retrospective study, the performance of modified 3-bend cystotome was compared with conventional 2-bend cystotome. During cataract surgery, in the 3-bend cy...

2014
Sarunas Tarasevicius Valdemaras Loiba Justinas Stucinskas Otto Robertsson Hans Wingstrand

BACKGROUND Previously was found that sonography is a reliable method to measure a capsular distance in total hip arthroplasty hips. The aim of our current study was to investigate the relation between the implanted size of the cup and the anterior capsular distance, as measured with ultrasound one year after THA. METHODS 50 osteoarthritis (OA) patients operated on with total hip arthroplasty ...

Journal: :BMC Ophthalmology 2005
Jeewan S Titiyal Rajesh Sinha Namrata Sharma Rasik B Vajpayee

BACKGROUND Capsule related complications are common following pediatric cataract surgery. We report a new technique of multiple anterior capsulorhexisotomies after lens aspiration and intraocular lens (IOL) implantation. METHODS After performing automated lens aspiration, an IOL was implanted into the capsular bag. A bent 26 gauge needle was introduced through one side port and multiple small...

Journal: :Arthroscopy techniques 2015
Omer Mei-Dan Tigran Garabekyan Mark McConkey Cecilia Pascual-Garrido

Symptomatic anterior instability of the hip is typically iatrogenic in nature and poses a challenging problem for the orthopaedist. With early recognition, capsular repair and plication are often effective in restoring stability. Cases involving multiple instability episodes or those with delayed presentation, however, may have patulous and deficient capsular tissue precluding successful capsul...

2017
Ehab M Ghoneim MD

Purpose: To describe a new intraocular lens that can be implanted in case of rupture of the posterior capsule and lack of capsular support. Methods: This experimental study was carried out on ten Flanders rabbits. The right eye of each rabbit underwent intra capsular lens extraction and two peripheral iridectomies, and the new lens was implanted with an optic rest in the posterior chamber. Addi...

Journal: :International Journal of Orthopaedics Sciences 2023

The Anterior Cruciate Ligament is the primary stabilizer of knee and prevents against anterior translation. It also important in counteracting rotational valgus stress. arthroscopically aided approach has advantages smaller skin capsular incisions, improved viewing intercondylar notch for placement tunnel attachment sites, less postoperative pain, fewer adhesions, earlier motion easier rehabili...

Journal: :Bulletin (Hospital for Joint Diseases (New York, N.Y.)) 2005
Arash Araghi Mark Prasarn Selvon St Clair Joseph D Zuckerman

Although the operative management of recurrent anterior glenohumeral instability has received significant attention in literature, the outcome of revision anterior shoulder repair is much less frequently reported. We report the results of our experience with this challenging problem. Retrospective chart review identified 29 patients who underwent revision anterior shoulder repair. Prior procedu...

Journal: :The Journal of bone and joint surgery. British volume 2005
P T H Lee M T Clarke P W P Bearcroft A H N Robinson

We have assessed the proximal capsular extension of the ankle joint in 18 patients who had a contrast-enhanced MRI ankle arthrogram in order to delineate the capsular attachments. We noted consistent proximal capsular extensions anterior to the distal tibia and in the tibiofibular recess. The mean capsular extension anterior to the distal tibia was 9.6 mm (4.9 to 27.0) proximal to the anteroinf...

Journal: :British journal of sports medicine 2002
C-H Choi D J Ogilvie-Harris

OBJECTIVES To assess the results of inferior capsular shift for multidirectional instability of the shoulder in athletes. METHODS Multidirectional instability was surgically corrected in 53 shoulders in 47 athletes who engaged in contact sports. A history of major trauma was found in eight patients, the others having had minor episodes. Before surgery, all patients had complex combinations of...

Objectives: The aim of this study was to assess the symmetry of ground reaction forces in patient with ACL rupture during vertical jump. Methods: Six men with ACLD (anterior cruciate ligament disease) participated in this study. Ground reaction forces components were assessed during Sargent jump by Kistler force plate. Data were analyzed running dependent Samples T-test and Repeated Measure in...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید