نتایج جستجو برای: anthropomorphic phantom
تعداد نتایج: 19149 فیلتر نتایج به سال:
The present report describes the fabrication technique and dosimetry aspects of a desktop numerically controlled milling machine (NC-Mill) based a compensator system that uses lead clay (Shield cray, Reactor Experiments, Inc., U.S.A.). Effective path lengths of patients were determined for CT image sets using the ray-tracing technique and converted to compensator thickness with the equivalent T...
PURPOSE To design a Head and Neck (H&N) anthropomorphic QA phantom that the Imaging and Radiation Oncology Core Houston (IROC-H) can use to verify the quality of intensity modulated proton therapy (IMPT) H&N treatments for institutions participating in NCI clinical trials. METHODS The phantom was created to serve as a remote auditing tool for IROC-H to evaluate an institution's IMPT planning ...
We have segmented CT torso+head and MRI head slices of two living human males. The manually segmented 129 x-ray CT transverse slices were used to create a computerized 3dimensional volume array modeling all major internal structures of the body. The original xray CT images were reconstructed in a 512x512 matrix with a resolution of 1 millimeter in the x,y plane. The z-axis resolution is 1 centi...
Background: In head and neck radiotherapy, immobilization devices can affect dose delivery. In this study, a comprehensive end-to-end test was developed to evaluate the accuracy of radiotherapy treatment. Materials and Methods: An Alderson Radiation Therapy (ART) anthropomorphic phantom with EBT3 film was used to mimic the actual patient treatment process. Ten patients treated for nasopharyngea...
PURPOSE To design an anthropomorphic pediatric spine phantom for use in the evaluation of proton therapy facilities for clinical trial participation by the Imaging and Radiation Oncology Core (IROC) Houston QA Center (formerly RPC). METHODS This phantom was designed to perform an end-to-end audit of the proton spine treatment process, including simulation, dose calculation by the treatment pl...
Physical anthropomorphic phantoms have been utilized for a variety of dosimet- ric studies across a range of procedures utilizing diagnostic imaging equipment. Unfortunately, these phantoms are often limited to a single reference size, which often may not be representative of the patient population at large. This work set out to develop an adipose tissue-equivalent substitute material that coul...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید