نتایج جستجو برای: camera based epid

تعداد نتایج: 2968489  

Journal: :Physics in medicine and biology 2014
A Agnew C E Agnew M W D Grattan A R Hounsell C K McGarry

This work investigated the differences between multileaf collimator (MLC) positioning accuracy determined using either log files or electronic portal imaging devices (EPID) and then assessed the possibility of reducing patient specific quality control (QC) via phantom-less methodologies. In-house software was developed, and validated, to track MLC positional accuracy with the rotational and sta...

Journal: :Medical physics 2001
M G Herman J M Balter D A Jaffray K P McGee P Munro S Shalev M Van Herk J W Wong

AAPM Task Group 58 was created to provide materials to help the medical physicist and colleagues succeed in the clinical implementation of electronic portal imaging devices (EPIDs) in radiation oncology. This complex technology has matured over the past decade and is capable of being integrated into routine practice. However, the difficulties encountered during the specification, installation, ...

Journal: :Anesthesiology 2016
Jessica M Booth Joshua C Pan Vernon H Ross Gregory B Russell Lynne C Harris Peter H Pan

BACKGROUND It is unclear whether recognition of epidural catheter failures is delayed with combined spinal epidural technique (CSE) compared to traditional epidural technique (EPID) when used for labor analgesia. The authors hypothesized that recognition of failed catheters is not delayed by CSE. METHODS Anesthetic, obstetric, and quality assurance records from 2,395 labor neuraxial procedure...

Journal: :Medical physics 2012
K Poels T Depuydt D Verellen M De Ridder

PURPOSE to use complementary cine EPID and gimbals log file analysis for in-vivo tracking accuracy monitoring. METHODS A clinical prototype of dynamic tracking (DT) was installed on the Vero SBRT system. This prototype version allowed tumor tracking by gimballed linac rotations using an internal-external correspondence model. The DT prototype software allowed the detailed logging of all appli...

Journal: :Medical physics 2008
Philip Vial Peter B Greer Peter Hunt Lyn Oliver Clive Baldock

The purpose of this study was to experimentally quantify the change in response of an amorphous silicon (a-Si) electronic portal imaging device (EPID) to dynamic multileaf collimator (dMLC) beams with varying MLC-transmitted dose components and incorporate the response into a commercial treatment planning system (TPS) EPID prediction model. A combination of uniform intensity dMLC beams and stat...

Farzaneh Allaveisi Nasrin Amini

Introduction: Electronic portal imaging devices (EPIDs) could be used to dose verification of radiotherapy treatment plans. In vivo dose verification is performed to reduce differences found between dose delivered to the patient and the prescribed dose. The aim of this study was to perform a fast and efficient technique for the verification of delivered dose to the patient usin...

Abbas Haghparast, Mahdi Mohammadi

Introduction: The most modern radiotherapy devices are equipped with an Electronic Portal Imaging Device (EPID) system which is located on opposite side of the machine’s head. EPID system is often used to setting up the position verification during or between radiotherapy sessions. Material and Methods: Various types of dosimeters have been used to setting up ...

Journal: :Medical physics 2006
Markus Wendling Robert J W Louwe Leah N McDermott Jan-Jakob Sonke Marcel van Herk Ben J Mijnheer

The use of electronic portal imaging devices (EPIDs) is a promising method for the dosimetric verification of external beam, megavoltage radiation therapy-both pretreatment and in vivo. In this study, a previously developed EPID back-projection algorithm was modified for IMRT techniques and applied to an amorphous silicon EPID. By using this back-projection algorithm, two-dimensional dose distr...

Ali Jomehzadeh, Alireza Amouheidari Anton Mans Ben Mijnheer Mohammad Mohammadi, Parvaneh Shokrani

Introduction: The use of electronic portal imaging devices (EPIDs) is a method for the dosimetric verification of radiotherapy plans both pretreatment and in-vivo. The aim of this study was to test a 2D EPID-based dosimetry algorithm for dose verification of some plans inside a homogenous and anthropomorphic phantom and in-vivo, as well. Materials and Methods: </strong...

2005
Wendel Dean Renner Kevin Norton Timothy Holmes

A method to convert integrated electronic portal imaging device (EPID) images to fluence for the purpose of reconstructing the dose to a phantom is investigated here for simple open fields. Ultimately, the goal is to develop a method to reconstruct the dose to patients. The EPID images are transformed into incident intensity fluence by spatial filtering with a deconvolution kernel. The kernel u...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید