نتایج جستجو برای: canal transportation

تعداد نتایج: 89772  

Journal: :The journal of contemporary dental practice 2014
Dina Al-Sudani Majed Almalki Saad Al-Shahrani Michael Ahlquist

AIM The present study was conducted with the aim of evaluating and comparing the shaping ability of two Nickel-titanium rotary instruments, with two disparate design features, on root canal geometry of extracted human maxillary first premolars using microcomputed tomography. STUDY DESIGN Twenty four bifurcated maxillary first premolars were divided into two groups and embedded in a rubber-bas...

2013
Samia M. Elsherief Mohamed K. Zayet Ibrahim M. Hamouda

Cone beam computed tomography is a 3-dimensional high resolution imaging method. The purpose of this study was to compare the effects of 3 different NiTi rotary instruments used to prepare curved root canals on the final shape of the curved canals and total amount of root canal transportation by using cone-beam computed tomography. A total of 81 mesial root canals from 42 extracted human mandib...

Journal: :Journal of endodontics 2016
Ana Grasiela da Silva Limoeiro Antônio Henrique Braitt Dos Santos Alexandre Sigrist De Martin Augusto Shoji Kato Carlos Eduardo Fontana Giulio Gavini Laila Gonzales Freire Carlos Eduardo da Silveira Bueno

INTRODUCTION Cleaning and shaping without making procedural errors have always been a challenge in endodontics, particularly when the root canals are curved. Several rotary instruments have been developed to minimize such errors. The purpose of this study was to compare the shaping ability of 2 rotary file systems, BioRace (BR; FKG, La Chaux-de-Fonds, Switzerland) and ProTaper Next (PTN; Dentsp...

2016
Juan-Gonzalo Olivier Marc García-Font Jose-Antonio Gonzalez-Sanchez Miguel Roig-Cayon Fernando Durán-Sindreu

BACKGROUND The objective of the study was to evaluate and compare how apical enlargement with K3 and K3XF nickel-titanium (NiTi) rotary instruments reduces the root thickness in the danger zone and affects canal transportation and centering ability in mandibular molar mesial canals in a manikin extracted tooth model. MATERIAL AND METHODS Seventy-two mesial root canals of first mandibular mola...

2012
David Uroz-Torres María Paloma González-Rodríguez Carmen María Ferrer-Luque

Objective: To compare the straightening of root canal curvature, the apical transportation, the loss of working length and the working time using two rotary systems. Study design: Sixty buccal root canals with angles of curvature between 30 to 99o were instrumented with Mtwo and Twisted File rotary instruments. A series of preand post-operative radiographs were superimposed to determine the str...

2014
Kiamars Honardar Hadi Assadian Shahriar Shahab Zahra Jafari Ali Kazemi Kiumars Nazarimoghaddam Mohammad Javad Kharrazifard Hossein Labbaf

OBJECTIVE Use of rotary Nickel-Titanium (NiTi) instruments for endodontic preparation has introduced a new era in endodontic practice, but this issue has undergone dramatic modifications in order to achieve improved shaping abilities. Cone-beam computed tomography (CBCT) has made it possible to accurately evaluate geometrical changes following canal preparation. This study was carried out to co...

Journal: :iranian endodontic journal 0
kiumars nazari moghaddam shahriar shahab golriz rostami

i ntroduction: the purpose of this in vitro study was to compare the canal transportation and centering ability of twisted file (tf) to that of reciproc system. methods and materials: forty noncalcified roots with mature apices, minimum length of 19 mm and an apical curvature of 15-30 degrees (according to schneider’s method), from freshly extracted mandibular and maxillary teeth, were selected...

2014
Zahra Sadat Madani Azam Haddadi Sina Haghanifar Ali Bijani

INTRODUCTION Due to the importance of apical transportation during root canal preparation, the aim of the current study was to use cone-beam computed tomography (CBCT) to assess the extent of apical transportation caused by ProTaper and Mtwo files. METHODS AND MATERIALS Forty extracted maxillary first molars with 19-22 mm length and 20-40 degrees of curvature were selected. The mesiobuccal ca...

Journal: :iranian endodontic journal 0
hadi mokhtari mahdi niknami aydin sohrabi ehsan habibivand hamid reza mokhtari zonouzi saeed rahimi

introduction: the aim of this in vitro study was to evaluate the transportation of mesiobuccal canals of mandibular first molars prepared with either biorace or mtwo rotary instruments or hand k-flexofile, by means of cone-beam computed tomography (cbct). methods and materials: forty-five mandibular molars were selected and randomly divided into three groups ( n =15). mesiobuccal roots of these...

2013
Anil Dhingra Nayasha Manchanda

The aim of this study was to describe canal anatomy modifications by Path Files (PF) using cone beam computed tomography (CBCT) in mandibular first molars. A total of 100 mesiobuccal (MB) root canals of mandibular first molars were prepared with PF. CBCT was used to scan the specimens before and after instrumentation. The root canal curvature, centric ability, apical transportation, root canal ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید