Journal: :Annals of thoracic and cardiovascular surgery : official journal of the Association of Thoracic and Cardiovascular Surgeons of Asia 2013
Sebastian Holinski Benjamin Claus Nicole Haeger Konrad Neumann Ralf Uebelhack Wolfgang Konertz

OBJECTIVES Reduction of cognitive function is a possible side effect after coronary artery surgery using cardiopulmonary bypass (CPB). We investigated the effect of roller versus centrifugal pumps for CPB on cognitive performance in patients undergoing coronary artery bypass grafting (CABG). METHODS 50 consecutive CABG patients operated with centrifugal pump were compared to 50 roller pump pa...

2002
N. W. VLACHAKIS

A group of empirical equations were developed in order to estimate the performance curves (H Q, n Q, P -Q, NPSHr -Q) of a centrifugal pump, using quite small amount of pumps geometric data. The results of the present study prove that centrifugal pumps performance curves direct estimation could be accomplished without using complex mathematical models. Furthermore more, all-basic parameters affe...

1997
Robin Brennan

The increased use of the centrifugal pump during coronary artery bypass surgery has been based primarily on theoretical data related to patient safety. There is minimal evidence suggesting improved outcome when compared to the traditional roller pump technology. We prospectively randomized 200 patients undergoing elective coronary artery bypass grafting into centrifugal pump (100 patients) and ...

Journal: :Energetika. Ekonomìka, tehnologìï, ekologìâ 2022

Developed a complex mathematical model of the electromechanical system oil production by means submerged centrifugal pump. Received an expression criterion efficiency taking into account stages extraction and repair well, as ratio volume extracted to consumed energy during cycle analysis processes. Mathematical system: asynchronous motor - pump hydraulic network is implemented in simulation pro...

Journal: :The journal of extra-corporeal technology 1997
D J Rawn H K Harris J B Riley D N Yoda M M Blackwell

The purpose of this study is to measure and compare the hemolysis produced by roller pumps with varied occlusion settings and a centrifugal pump. The null hypothesis is that there is no difference in the Index of Hemolysis (IH = gm Hb/100 L pumped) produced by a roller pump (RP) at four different occlusion settings and a centrifugal pump (CP) at the same blood flow rate (4.5 L/min) and afterloa...

Deniss Pilscikovs Egils Dzelzitis

The goal of this research is the derivation of method for evaluation of efficiency improvement potential for district heating systems with focus on variable speed centrifugal pump. The effectiveness of the usage of the proportional pressure control is compared with the constant pressure control. This is why, energy calculation analyses have been realized for variable speed centrifugal pumps, an...

2001

Case Services' software provides production optimization for a variety of different methods of artificial lift. This paper discusses the dominant factors in electrical centrifugal submersible pump design and monitoring. Emphasis is placed on three areas: • Well inflow performance behavior. • Fluid Pressure-Volume-Temperature and phase behavior. • Pump equipment performance specifications. An ex...

Journal: :The journal of extra-corporeal technology 2010
Martin C Gill Hayden Dando Dittmer John

The occurrence of gaseous microemboli (GME) within the extracorporeal membrane oxygenation circuit is largely overlooked, as are methods to ameliorate this occurrence. We aimed to determine if the air handling capability of the Quadrox D oxygenator was dependent upon whether it was used in conjunction with a centrifugal or roller pump; and if application of a Pall air eliminating filter (AEF) w...

Journal: :Circulation 2012
Keith D Aaronson Mark S Slaughter Leslie W Miller Edwin C McGee William G Cotts Michael A Acker Mariell L Jessup Igor D Gregoric Pranav Loyalka O H Frazier Valluvan Jeevanandam Allen S Anderson Robert L Kormos Jeffrey J Teuteberg Wayne C Levy David C Naftel Richard M Bittman Francis D Pagani David R Hathaway Steven W Boyce

BACKGROUND Contemporary ventricular assist device therapy results in a high rate of successful heart transplantation but is associated with bleeding, infections, and other complications. Further reductions in pump size, centrifugal design, and intrapericardial positioning may reduce complications and improve outcomes. METHODS AND RESULTS We studied a small, intrapericardially positioned, cont...

2013
S. Abouda F. Nollet A. Chaari N. Essounbouli Y. Koubaa

In this paper we propose the study of a centrifugal pump control system driven by a three-phase induction motor, which is supplied by a PhotoVoltaic PV generator. The system includes solar panel, a DC / DC converter equipped with its MPPT control, a voltage inverter to three-phase Pulse Width Modulation PWM and a centrifugal pump driven by a three phase induction motor. In order to control the ...