Journal: :Journal of physics 2023

Abstract The circuit breaker is a device that cuts off and connects the load in power system, fault circuit, prevents accident from expanding, ensures safe operation. Detecting failures necessary to ensure systems’ safety. Before identification, must be identified positioned first. In this paper, identification technology based on SSD adopted, used identify mark voltage name quickly.

2009
Mark Higginson David B. Durocher

This paper will discuss the importance of reliable and repeatable performance of molded case circuit breakers in today’s power distribution systems. The paper will review existing standards for maintenance of molded case breakers including procedures outlined in NEMA AB4 and IEEE1458. Common misconceptions and system application issues regarding these devices will be discussed. Several examples...

2011
DC Power M. Kempkes I. Roth M. Gaudreau

How can the large power needs of future electric ships for propulsion, radar, and weapons systems be met given the prohibitive size and weight of the required number of standard 60 Hz AC generators and transformers? A solution may lie in a rugged, efficient, and compact solid-state, 10-20 kV Medium Voltage DC (MVDC) circuit breaker (Figure 1). In this paper, Diversified Technologies, Inc. will ...

2012

Since the May 6 th , 2010 flash crash in the U.S., appropriate measures ensuring safe, fair and reliable markets become more relevant from the perspective of investors and regulators. Circuit breakers in various forms are already implemented for individual markets to ensure price continuity and prevent potential market failure and crash scenarios. However, coordinated inter-market safeguards ha...

2010
G. R. Padmini M. Satyam K. Lalkishore

The general trend in electrical appliances is to go for electrical equivalents of mechanical or electromechanical gadgets. One of the long standing electronic component is the circuit breaker, a protective device that trips the ac supply once the current through the system goes beyond the rated value. In this paper an all electronic circuit breaker using bidirectional switch is demonstrated. Th...

2013
Adrian T. Plesca

This paper describes a three-dimensional thermal model of the current path included in the low voltage power circuit breakers. The model can be used to analyse the thermal behaviour of the current path during both steady-state and transient conditions. The current path lengthwise temperature distribution and timecurrent characteristic of the terminal connections of the power circuit breaker hav...

2001
R. L. Middleton

Very low temperatures stress a circuit breaker in a complex manner. Mixed-gas circuit breakers were developed for use at temperatures as low as -50C. These breakers utilize a gas mixture of SF6 and CF4 or SF6 and N2 to prevent condensation of the SF6 gas and have been type tested at -50C to ensure travel characteristics, operating times, and gas tightness are acceptably affected. Today’s mixed-...

2014
CORNELIA A. BULUCEA MARC A. ROSEN DORU A. NICOLA NIKOS E. MASTORAKIS CARMEN A. BULUCEA

This paper is a sequel to a study by the authors of electric power systems comprising the generator circuit-breakers (GCBs) at power plant generator terminals. A sustainable assessment of the current interruption requirements of a GCB addresses the main stresses on the generator circuit breaker, revealing that the GCB current interruption requirements are significantly higher than for the distr...

2005
Xuegong Wang

Circuit breakers can fail to interrupt fault current when the power system has transient recovery voltage (TRV) characteristics that exceed the rating of the circuit breaker. There were two incidents of failures of outdoor switchgear at a power plant substation. The cause of the failure for these breakers was investigated in order to determine if transient recovery voltage is a contributing fac...

Journal: :International endodontic journal 2005
K C Nam S H Ahn J H Cho D W Kim S J Lee

AIM To measure excessive electrical stimulus time during pulp testing via electromyography (EMG) in the anterior belly of the digastric muscle, voice and finger movement, and to determine whether excessive stimulus time could be attenuated by a specially designed automatic circuit breaker on the basis of the EMG signal. METHODOLOGY The signals from three human responses (EMG, finger and voice...

نمودار تعداد نتایج جستجو در هر سال