نتایج جستجو برای: dialysate
تعداد نتایج: 2491 فیلتر نتایج به سال:
BACKGROUND In automated peritoneal dialysis (APD) one of the most important factors that influence the efficiency of the treatment is the total volume of dialysate infused per session and the dwell time. This study is aimed at examining the relationships between i.p. pressure (IPP), dialysate flow characteristics, and different dialysate fill volumes in order to optimize APD. METHODS We studi...
INTRODUCTION Most home haemodialysis (HD) modalities are limited to home use since they are based on a single-pass (SP) technique, which requires preparation of large amounts of dialysate. We present a new dialysis method, which requires minimal dialysate volumes, continuously recycled during treatment [multipass HD (MPHD)]. Theoretical calculations suggest that MPHD performed six times weekly ...
INTRODUCTION It has been suggested that a dialysate calcium concentration of 1.5 mmol/L is a compromise between bone protection and cardiovascular risk. This study aimed to investigate the effect of reducing dialysate calcium concentration to 1.5 mmol/L on mineral metabolism and hemodynamic parameters. MATERIALS AND METHODS Dialysate calcium concentration was changed from 1.75 mmol/L to 1.5 m...
AIM To determine the incidence of intradialytic hypertension (IDH) during hemodialysis (HD) in end-stage renal disease (ESRD) patients using acetate dialysate compared to those using bicarbonate dialysate. METHODS This study was a double-blind cross-over randomized clinical trial. The effect of acetate and bicarbonate dialysate on blood pressure was analyzed in two consecutive HD sessions. Th...
BACKGROUND Increased levels of oxidized proteins have been reported in the serum of patients with end-stage renal disease, though little is known regarding the oxidized protein content of the dialysate in patients on peritoneal dialysis (PD) and no information is available as to how this may correlate with important clinical and laboratory variables, including abnormal peritoneal membrane funct...
BACKGROUND Dialysate [Na+] is often overlooked as a contributor to hypertension in patients on haemodialysis (HD). We report observational experience with a facility level decrease in dialysate [Na+] from 141 mmol/l to 138 mmol/l, in the absence of concurrent change with respect to dietary sodium regulation. METHODS The sample comprised all patients (n=52) dialysing at a single HD facility ov...
BACKGROUND AND OBJECTIVES Previous in vitro and clinical studies showed that the urea mass transfer-area coefficient (K(o)A) increased with increasing dialysate flow rate. This observation led to increased dialysate flow rates in an attempt to maximize the delivered dose of dialysis (Kt/V(urea)). Recently, we showed that urea K(o)A was independent of dialysate flow rate in the range 500 to 800 ...
abstract background: hypertension is very common in patients with end-stage renal disease and accelerates cardiovascular morbidity and mortality. the most important factor in achieving normal blood pressure in these patients is reaching dry weight. sodium and extracellular fl uid balance play a vital role in this regard. considering the lack of consensus about the effi cacy of stepwise sodium p...
We describe a method for quantitatively estimating 24 ninhydrin-reacting substances, including the commoner amino acids, in fecal dialysate prepared from ingested dialysis bags retrieved from fresh stool. It is accurate to 2 mumol of alpha-amino nitrogen per liter of fecal dialysate, and for most substances recovery of added standards is 100%. It involves dilution, ultrafiltration, and automate...
BACKGROUND Automated peritoneal dialysis (APD) has the possibility of increasing the dialysis efficacy by using higher fill volumes, frequent dialysate exchanges, and tidal techniques. It is then possible to treat patients adequately without residual renal function. The drawbacks of the required high amounts of dialysis solution of up to 30 litres per session are the high costs of lactate-based...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید