نتایج جستجو برای: diode detector

تعداد نتایج: 78175  

2009
Vladimir Feygelman Kenneth Forster Daniel Opp Görgen Nilsson

In this paper, we described and characterized a novel biplanar diode array, and demonstrated its applicability to dosimetric QA of the step-and-shoot IMRT. It is the first commercially available device of its kind specifically designed for measurements at varying gantry angles. The detector consists of a cylindrical PMMA phantom with two orthogonal detector boards. There are a total of 1069 p-t...

2011
Hugh T. Philipp Marianne Hromalik Mark Tate Sol M. Gruner

X-ray free electron lasers (XFELs) promise to revolutionize X-ray science with extremely high peak brilliances and femtosecond X-ray pulses. This will require novel detectors to fully realize the potential of these new sources. There are many current detector development projects aimed at the many challenges of meeting the XFEL requirements [1,2]. This paper describes a pixel array detector (PA...

2011

A new system for CO2 measurement (0-100%) by based on a paired emitter-detector diode arrangement as a colorimetric detection system is described. Two different configurations were tested: configuration 1 (an opposite side configuration) where a secondary inner-filter effect accounts for CO2 sensitivity. This configuration involves the absorption of the phosphorescence emitted from a CO2-insens...

Journal: :The Analyst 2006
Martina O'Toole King-Tong Lau Benjamin Shazmann Roderick Shepherd Pavel N Nesterenko Brett Paull Dermot Diamond

A novel low power, low cost, highly sensitive, miniaturized light emitting diode (LED) based flow detector has been used as optical detector for the detection of sample components in high performance liquid chromatography (HPLC). This colorimetric detector employs two LEDs, one operating in normal mode as a light source and the other is reverse biased to work as a light detector. Instead of mea...

2011
K. Osberg N. Schemm S. Balkir S. Hallbeck Peter A. Dowben Kevin Osberg Nathan Schemm Sina Balkir

In this paper, a hand-held neutron radiation sensor application is described. The sensor system utilizes a new class of boron-carbide diode that interacts with incoming neutrons. To interface with the boron-carbide diode an integrated front-end is designed in a 1.5/spl mu/m standard CMOS technology. With the diode and front-end microchip, a hand-held neutron detection system was realized with a...

2006
Hua Feng

A double-layer silicon detector consisting of two 500μm-thick silicon PIN photodiodes with independent readouts was mounted in a vacuum chamber and tested with X-ray sources. The detector is sensitive from 1–30 keV with an effective area of 6 mm. The detector performs best at −35 ◦C with an energy resolution of 220 eV (FWHM, full width at half maximum) at 5.9 keV, and is able to operate at room...

Journal: :Molecules 2011
Li-Chun Zhao Wei Li Yu-Fang He Xiao-Hua Li Zi Wang Wen-Cong Liu Yi-Nan Zheng Jian Liang

In the present study, we developed a liquid chromatography-diode array detector-electrospray ionization/mass spectrometric (LC-DAD-ESI/MS) method for analysis of saikosaponins in Bupleurum falcatum. The LC method employed a ZORBAX SB-Aq analytical column (150 x 4.6 mm i.d., 5 μm) at a flow rate of 0.8 mL/min coupled with a diode array detector at 204 nm. A step gradient of acetonitrile-water (v...

Journal: :International Journal of Research in Engineering and Technology 2015

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید