نتایج جستجو برای: diode dosimeter

تعداد نتایج: 23008  

Journal: :Chest 2005
Nathan D Allen Beth E Davis Thomas S Hurst Donald W Cockcroft

BACKGROUND Two bronchoprovocation methods are widely used. Compared to the tidal breathing method, the dosimeter method delivers approximately half the dose and involves five deep inhalations. Both the lower dose and the bronchoprotective deep inhalations contribute to the lesser airway response of the dosimeter. OBJECTIVE To determine the relative role of dose and deep inspiration in the dif...

Journal: :Physics in medicine and biology 2015
Y De Deene P S Skyt R Hil J T Booth

Three dimensional radiation dosimetry has received growing interest with the implementation of highly conformal radiotherapy treatments. The radiotherapy community faces new challenges with the commissioning of image guided and image gated radiotherapy treatments (IGRT) and deformable image registration software.A new three dimensional anthropomorphically shaped flexible dosimeter, further call...

2014
Elizabeth M. McKenzie Peter A. Balter Francesco C. Stingo Jimmy Jones David S. Followill Stephen F. Kry

The purpose of this study was to determine the reproducibility of patient-specific, intensity-modulated radiation therapy (IMRT) quality assurance (QA) results in a clinical setting. Six clinical patient plans were delivered to a variety of devices and analyses, including 1) radiographic film; 2) ion chamber; 3) 2D diode array delivered and analyzed in three different configurations (AP deliver...

Journal: :Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine 2001
T T Cheung K N Yu D Nikezic

A true bronchial dosimeter has been designed, consisting of four 400-mesh wire screens and a filter paper. With a face velocity of 3.3 cm s(-1) for home exposure and 4.6 cm s(-1) for mine exposure, the deposition pattern on the wire screens were found to satisfactorily match the variation of the dose conversion factor (in units of mSv WL M(-1)) with the size of radon progeny from 1 to 1000 nm. ...

2010
Susana Lopez-Aparicio Terje Grøntoft Elin Dahlin

96 Since its development, the Early Warning dosimeter for Organic materials (EWO dosimeter) has been used as both a research and general measurement tool for the evaluation of indoor air quality for preservation of cultural heritage artefacts. The EWO dosimeter measures the integrated degradation impact of the environment, comparable to that observed on organic materials due to the synergistic ...

2014
Marc F. Desrosiers

Post-irradiation stability of high-dose dosimeters has traditionally been an important measurement influence quantity. Though the exceptional stability of the alanine dosimeter response with time has rendered this factor a non-issue for routine work, the archival quality of the alanine dosimeter has not been characterized. Here the alanine pellet dosimeter response is measured up to seven years...

Journal: :RADIOISOTOPES 1965

2013
N. Malathi P. Sahoo K. Praveen N. Murali

The paper presents an innovative approach towards development of real time dosimetry using a chemical dosimeter for measurement of absorbed radiation dose in the range between 1 and 400 Gy. Saturated chloroform solution in water, a well known chemical dosimeter, is used to demonstrate the concept of online measurement of radiation dose. The measurement approach involves online monitoring of inc...

Journal: :Physics in medicine and biology 2016
Luc Beaulieu Sam Beddar

While scintillation dosimetry has been around for decades, the need for a dosimeter tailored to the reality of modern radiation therapy-in particular a real-time, water-equivalent, energy-independent dosimeter with high spatial resolution-has generated renewed interest in scintillators over the last 10 years. With the advent of at least one commercial plastic scintillation dosimeter and the eve...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید