نتایج جستجو برای: dispersive liquid phase microextraction
تعداد نتایج: 790263 فیلتر نتایج به سال:
hydrochlorothiazide (hct) is a diuretic agent which is shown to be effective in the treatment of hypertension. literature reports have demonstrated that urinary excretion data may be used to assess the bioavailability of various formulations containing this thiazide. also hct consumption by the athletes is one of the drugs which should be regulated by world anti-doping agency (wada), because of...
We report the application of the dispersive liquid-liquid microextraction coupled to hollow-fibre membrane-assisted liquid-phase microextraction and its application for extraction of atrazine and triclosan. Under optimum conditions, namely, 25 μL of a 1 : 4 chlorobenzene : ethyl acetate mixture dispersed in 1 mL of aqueous sample, 10% (m/v) NaCl, a magnetic stirrer speed at 600 rpm, and 10 minu...
abstract polycyclic aromatic hydrocarbons (pahs) are classified as persistent and carcinogenic organic pollutants. pahs contamination has been reported in water. many of relevant regulatory bodies such as eu and epa have regulated the limit levels for pahs in drinking water. in this study, 13 priority polycyclic aromatic hydrocarbons (pahs) were determined in tap water samples of tehran and wat...
A new format of fast three-phase microextraction by combining low-density solvent-based dispersive liquid-liquid microextraction (DLLME) and single-drop microextraction (SDME) was for the first time developed for the determination of chlorophenols in environmental water samples. The extraction procedure includes a 2 min DLLME pre-extraction and a 10 min SDME back-extraction. A portion of low-de...
Ionic liquid-based dispersive liquid–liquid microextraction (IL– –DLLME) coupled with high performance liquid chromatography (HPLC) with UV detection was developed for the simultaneous extraction and determination of nickel, cobalt, copper and zinc ions. In the proposed approach, salophen (N,N'-bis(salicylidene)-1,2-phenylenediamine) was used as a chelating agent, the ionic liquid, 1-hexyl-3-me...
A sensitive determination method was developed for the analysis of pyrethroid pesticide residues in tomato samples using ionic liquid-based dispersive liquid-liquid microextraction. A hydrophobic ionic liquid (1-butyl-3-methylimidazolium hexafluorophosphate) and acetonitrile were used as the extraction solvent and dispersive solvent, respectively. The following experimental parameters affecting...
the applicability of hollow fiber-based liquid phase microextraction (hf-lpme) was evaluated for the extraction and preconcentration of loratadine prior to determination by hplc. in order to obtain high extraction recovery, the parameters affecting the hf-lpme including type of organic phase, ph of the source and receiving phases, stirring rate, extraction time and salt addition were studied an...
In the proposed method, carbon tetrachloride and ethanol were used as extraction and dispersive solvents. Several factors that may be affected on the extraction process, such as extraction solvent, disperser solvent, the volume of extraction and disperser solvent, pH of the aqueous solution and extraction time were optimized. Under the optimal conditions, linearity was maintained between 1.0 ng...
a simple, inexpensive and efficient method was used for extraction and determination of fexofenadine and levocetirizine with three–phase hollow fiber liquid-phase microextraction and high-performance liquid chromatography. several parameters influencing the extraction recoveries such as the nature of organic extraction solvent, ph of donor and acceptor phases, stirring rate, extraction time and...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید