نتایج جستجو برای: distal femoral fracture

تعداد نتایج: 191216  

2009
Juan Pretell Mazzini Juan Rodriguez Martin Carlos Resines Erasun

To the best of our knowledge, only 3 cases, including the present case, have been reported with a three part broken pattern. However, this is the first case associated with a distal locking screw broken. We report the case of a 31-year-old patient who sustained an open femoral shaft fracture . The fracture was stabilized with a Kuntcher femoral nail. After 7 months of the initial surgery he pre...

2014
Hakan Cift Engin Eceviz Necdet Sağlam Cem Coşkun Avcı Salih Söylemez Esat Uygur Korhan Ozkan

Objectives: In this study we aimed to present our treatment results of intramedullary nailing of femoral shaft fractures with compressive nailing using proximal static hole and only distal dynamic hole with one screw. Methods: Forty-three patients who had a fracture of the femoral shaft were managed between 2005 and 2008 with intramedullary nailing and the use of only one screw for distal inter...

Journal: :Journal of orthopaedic surgery 2006
A K Bhat S K Rao K Bhaskaranand

PURPOSE To study clinical and mechanical factors that predispose to failure of interlocking nails. METHODS Between October 1996 and December 2002, 286 femoral fractures, 211 tibial fractures, and 47 humeral fractures were repaired using variously designed interlocking nails. Fracture pattern, level and site, nail size and type, weight bearing after nailing, and union status were reviewed afte...

2016
Mark R Adams Conor Dunn Michael S Sirkin Mark C Reilly

INTRODUCTION Long-term bisphosphonate therapy for osteoporosis is associated with an increased risk of low-to-no energy atypical subtrochanteric and femoral shaft fractures with characteristic radiologic findings. There are few reports of patients with long-term bisphosphonate-induced periprosthetic fractures, all of them had a hip arthroplasty prosthesis. In this report, we present a unique ca...

Journal: :razavi international journal of medicine 0
mohammad hosein ebrahimzadeh orthopedic research center, department of orthopedic surgery, mashhad university of medical sciences, mashhad, ir iran hamid farzadfar orthopedic research center, department of orthopedic surgery, mashhad university of medical sciences, mashhad, ir iran hami ashraf department of research and education, razavi hospital, mashhad, ir iran gholam reza khoshsima orthopedic research center, department of orthopedic surgery, mashhad university of medical sciences, mashhad, ir iran ali birjandinejad orthopedic research center, department of orthopedic surgery, mashhad university of medical sciences, mashhad, ir iran; orthopedic research center, department of orthopedic surgery, mashhad university of medical sciences, mashhad, ir iran. tel: +98-5138523300, fax: +98-5138549234

conclusions we found the magnetic field assistant device to be an accurate, radiation-independent jig for close passing of guide wire after close reduction of femoral fracture. it can reduce the need for radiation during placement of guide wire for closed intramedullary nailing of the long bones. more studies are required to improve and evaluate the technique and equipment. results outcomes of ...

Journal: :Journal of computer assisted tomography 2012
Nancy Chauvin Diego Jaramillo

The authors describe a case of distal femoral physeal injury with disruption of the perichondrium in a 9-year-old girl after a sledding accident. The patient presented with knee pain, limited range of motion, and inability to bear weight. Initial radiographs were normal. A magnetic resonance imaging of the knee demonstrated abnormal signal and widening of the distal femoral physis with elevatio...

2013
Saravana Vail Karuppiah Alan Johnstone Johnstone

Introduction: The indications for intramedullary nail fixation of fractures of the femoral shaft have been greatly expanded by techniques of interlocking nailing. However, distal locking screw fixation remains the most technically demanding and problematic portion of the procedure and maybe responsible for as much as one-half of the exposure of the surgeon’s hands to radiation during the proced...

Journal: :Journal of the College of Physicians and Surgeons--Pakistan : JCPSP 2016
Zhentao Zhou Xiaozhong Zhou Bingchen Shan Haibin Zhou Zhengfeng Lu Qirong Dong

OBJECTIVE To describe the applications and effects of electromagnetic navigation (EN) technology in distal locking for the treatment of long diaphyseal fracture (LDF) with interlocking intramedullary nailing (IIN). STUDY DESIGN An interventional study. PLACE AND DURATION OF STUDY The Second Affiliated Hospital of Soochow University, China, from March 2013 to July 2014. METHODOLOGY Patient...

2017
Sahil Kooner Eric Gibson Marcia Clark

BACKGROUND Distal femoral fracture is a rare, but significant, postoperative complication of anterior cruciate ligament reconstruction. However, there has not been a reported case of periprosthetic total knee arthroplasty fracture associated with a previous anterior cruciate ligament repair. CASE PRESENTATION We report the case of a 51-year-old white man with a history of total knee arthropla...

2016
Yong-Gang Ma Ge-Liang Hu Wei Hu Fan Liang

PURPOSE To explore the possible surgical factors related with nonunion in femoral shaft fracture following intramedullary nailing. METHODS We retrospectively analyzed totally 425 patients with femoral shaft fracture in level I urban trauma center, including 254 males and 171 females, with an average age of 37.6 (ranging from 21 to 56) years old. The inclusion criteria included: (1) traumatica...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید