نتایج جستجو برای: dose accuracy dose calculation algorithms

تعداد نتایج: 1018748  

2017
David Paulu Parham Alaei

There are an increasing number of radiation therapy patients with hip prosthesis. The common method of minimizing treatment planning inaccuracies is to avoid radiation beams to transit through the prosthesis. However, the beams often exit through them, especially when the patient has a double-prosthesis. Modern treatment planning systems employ algorithms with improved dose calculation accuraci...

Journal: :International Journal of Radiation Oncology*Biology*Physics 2014

Journal: :Machine Learning: Science and Technology 2021

A Chairmadurai C Bhatt D Shrotiya L Chaudhari N Painuly, N Singh, T Verma

Aims: The aims of the present work are (1) to evaluate dose calculation accuracy of two commonly used algorithms for 15 MV small photon fields in a medium encompassing heterogeneity and (2) to compare them with measured results obtained from gafchromic film EBT2.Materials and Methods: Authors employed kailwood (Pinus Wallichiana) to mimic lung. Briefly, seven Kailwood plates, each measuring 25x...

C. Yavas, G. Yavas, H. Acar,

Background: In radiation therapy, the peripheral dose is important when anatomical structures with very low dose tolerances are involved. In this study, the two available calculation algorithms of the Varian Eclipse 8.6 treatment planning system(TPS), the anisotropic analytic algorithm (AAA) and pencil-beam convolution (PBC) was used to compare measured and calculated peripheral dose distributi...

Journal: :journal of medical signals and sensors 0

an important need in radiation therapy is a fast and accurate treatment planning system. this system using ct data and characteristics of the radiation beam, calculates the dose in all points of the patient’s volume. two main factors in planning system are “accuracy” and “speed”. according to these factors, various generation of treatment planning systems are developed.   this article is the re...

M. Izmirli, M. Nart, S. Avcu, T. Çakır,

Background: Use of contrast agents (CAs) during CT simulation for treatment planing system leads to changes in  electron density. In this study we aimed to investigate the effect on  calculated dose of various concentrations of CAs on treatment planing systems in different dose calculation algorithms. Materials and Methods: Contrast agent (0.769 mg/ml Iopromid) - water mixtures at con...

Journal: :Medical physics 2010
H Schiefer A Fogliata G Nicolini L Cozzi W W Seelentag E Born F Hasenbalg J Roth B Schnekenburger K Münch-Berndl V Vallet M Pachoud B Reiner G Dipasquale B Krusche M K Fix

PURPOSE In 2008, a national intensity modulated radiation therapy (IMRT) dosimetry intercomparison was carried out for all 23 radiation oncology institutions in Switzerland. It was the aim to check the treatment chain focused on the planning, dose calculation, and irradiation process. METHODS A thorax phantom with inhomogeneities was used, in which thermoluminescence dosimeter (TLD) and ioniz...

2018
Lilie Wang Anthony J. Cmelak George X. Ding

Radiation dermatitis during radiotherapy is correlated with skin dose and is a common clinical problem for head and neck and thoracic cancer patients. Therefore, accurate prediction of skin dose during treatment planning is clinically important. The objective of this study is to evaluate the accuracy of skin dose calculated by a commercial treatment planning system (TPS). We evaluated the accur...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید