نتایج جستجو برای: electronic portal imaging

تعداد نتایج: 704364  

2011
Indra J. Das Minsong Cao Chee‐Wai Cheng Vladimir Misic Klaus Scheuring Edmund Schüle Peter A.S. Johnstone

Electronic portal imaging device (EPID) plays an important role in radiation therapy portal imaging, geometric and dosimetric verification. Consistent image quality and stable radiation response is necessary for proper utilization that requires routine quality assurance (QA). A commercial 'EPID QC' phantom weighing 3.8 kg with a dimension of 25 × 25 × 4.8 cm³ is used for EPID QA. This device ha...

Journal: :Physics in medicine and biology 2000
M Partridge J R Symonds-Tayler P M Evans

An evaluation of the capabilities of a commercially available camera-based electronic portal imaging system for intensity-modulated radiotherapy verification is presented. Two modifications to the system are demonstrated which use a novel method to tag each image acquired with the delivered dose measured by the linac monitor chamber and reduce optical cross-talk in the imager. A detailed perfor...

2000
Michael G. Herman Jon J. Kruse Christopher R. Hagness

The Electronic Portal Imaging Device (EPID) provides localization quality images and computer-aided analysis, which should in principal, replace portal film imaging. Modern EPIDs deliver superior image quality and an array of analysis tools that improve clinical decision making. It has been demonstrated that the EPID can be a powerful tool in the reduction of treatment setup errors and the qual...

Journal: :Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology 2008
Wouter van Elmpt Leah McDermott Sebastiaan Nijsten Markus Wendling Philippe Lambin Ben Mijnheer

Electronic portal imaging devices (EPIDs) have been the preferred tools for verification of patient positioning for radiotherapy in recent decades. Since EPID images contain dose information, many groups have investigated their use for radiotherapy dose measurement. With the introduction of the amorphous-silicon EPIDs, the interest in EPID dosimetry has been accelerated because of the favourabl...

2005
Zhanrong Gao Janos Szanto Lee Gerig

Electronic portal imaging devices (EPIDs) are potentially valuable tools for linear accelerator quality assurance and for measuring and analyzing geometric variations in radiation treatment delivery. Geometric analysis is more robust if referenced against an absolute position such as the isocenter (collimator axis of rotation), allowing the observer to discriminate between various setup errors ...

Journal: :Radiation Oncology (London, England) 2006
Karen L Ullman Holly Ning Robert C Susil Asna Ayele Lucresse Jocelyn Jan Havelos Peter Guion Huchen Xie Guang Li Barbara C Arora Angela Cannon Robert W Miller C Norman Coleman Kevin Camphausen Cynthia Ménard

BACKGROUND We sought to determine the intra- and inter-radiation therapist reproducibility of a previously established matching technique for daily verification and correction of isocenter position relative to intraprostatic fiducial markers (FM). MATERIALS AND METHODS With the patient in the treatment position, anterior-posterior and left lateral electronic images are acquired on an amorphou...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید