Background: Dose assessment using proper dosimeters is especially important in radiation protection optimization and imaging justification in diagnostic radiology.Objective: The aim of this study is to obtain the Entrance Skin Dose (ESD) of patients undergoing lumbar spine imaging using two thermoluminescence dosimeters TLD-100 (LiF: Mg, Ti) and GR-200 (LiF: Mg, Cu, P) and also to obtain the ab...
OBJECTIVE To compare the slot-scan digital radiography (SSDR) of the lower extremity region and the computed radiography (CR) method with respect to the image quality and radiation exposure. MATERIALS AND METHODS We enrolled 54 patients who underwent both the SSDR and CR of the lower extremities. The study evaluated and statistically compared the image quality of four features (outer cortex, ...
PURPOSE To compare radiation dose and image quality between a slot-scanning system (SSS) and a dynamic flat-panel detector (DFD) in assessing scoliosis in children. METHODS An experimental study was first performed with a phantom to assess the quality of each device. The clinical part included a prospective observational dosimetric and qualitative comparative study with acquisition of whole-s...
introduction: delivering maximum dose to tumor and minimum dose to normal tissues is the most important goal in radiotherapy. according to icru, the maximum acceptable uncertainty in the delivered dose compared to the prescribed dose should be lower than 5%, and this is because of the relationship between absorbed dose, tumor control and normal tissue damage. absorbed dose accuracy is investiga...
The purpose of this work is to compare computed radiography (Kodak CR 400) and film/screen combination (Speed 400) systems in regards of patient dose, technique settings, and contrast-detail detectability. A special contrast-detail phantom with drilled holes of varying diameter (detail) and varying depth (contrast) was utilized. Various thicknesses of the Lucite sheets were utilized to simulate...
The use of diagnostic reference levels (DRLs) is part of the optimisation process of radiation protection, in that it identifies practices that are in need of corrective action, resulting in dose reduction. Their use is provided for in Irish and European legislation. In this project, measurements were carried out at 42 of the 46 licensed intra-oral xray machines in Co. Wicklow using an Unfors M...
In vivo dosimetry seems an appropriate method for quality assurance in radiotherapy with CO-60, which can be considered as a routine program in radiotherapy centers. In this study, entrance and exit dose in tangential fields were measured in phantom for 30 breast cancer patients by using TLD in radiotherapy section of Imam Khomeini Hospital. TLD crystals were calibrated against SSDL (Secondary...
Sedimentation is one of the most important problems in harbors that results in considerable economic costs. Harbor planforms affects the flow pattern in the harbor basin and consequently, plays an important role in sediment transport and sedimentation. In the present study, a two dimensional depth-averaged hydrodynamic and sediment transport model has been developed to investigate the effect of...
Introduction: Nowadays, we are witnessing a progressive application of radiology techniques in various communities as well as in Iran. Medical radiological examinations are one of the important sources of public radiological dose. Entrance skin doses and effective doses for patients in diagnostic radiology examinations should be assessed for the imaging techniques optimization and patient&rsquo...