نتایج جستجو برای: fastener

تعداد نتایج: 455  

Journal: :Human factors 1997
Seoungyeon A. Oh Robert G. Radwin Frank J. Fronczak

A deterministic mechanical model based on physical tool parameters was used for estimating static and dynamic hand forces from kinematic measurements. We investigated the effects of target torque (25, 40, and 55 Nm) and threaded fastener joint hardness (35-, 150-, 300-, 500-, and 900-ms torque buildup time) on hand force. Estimated hand force was affected by target torque and joint hardness. Pe...

2016
M E Ibrahim G D Surtees S K Burke

Fatigue cracking in metallic aircraft structure often originates at fastener holes and can be detected using the nondestructive inspection technique of bolt-hole eddy-current (BHEC) testing. BHEC testing is based on detection of a disturbance in the induced current or magnetic field caused by a surface-breaking crack in the bore of the hole. However, if the surface of the hole contains benign m...

Journal: :The International Journal of Multiphysics 2023

Fastener technology is a key of Ballastless track structure in high-speed railway, and the elastic strip component to realize fastener function. To this end, special loading fixture fabricated explore performance under fatigue load. The working state was simulated through testing machine, stress-controlled modes four amplitudes (25±5kN, 25±7.5kN, 25±10kN, 25±12.5kN) are investigated. The p...

Journal: :Physical review letters 2012
Sujit S Datta Shin-Hyun Kim Jayson Paulose Alireza Abbaspourrad David R Nelson David A Weitz

Colloidal capsules can sustain an external osmotic pressure; however, for a sufficiently large pressure, they will ultimately buckle. This process can be strongly influenced by structural inhomogeneities in the capsule shells. We explore how the time delay before the onset of buckling decreases as the shells are made more inhomogeneous; this behavior can be quantitatively understood by coupling...

Journal: :The British journal of ophthalmology 1985
H Lincoff I Kreissig M Farber

One hundred patients with aphakic detachment were treated with temporary balloon buckles. The balloons were deflated and withdrawn after seven to 10 days. Permanent attachment depended on cryo- or laser-induced adhesions round the break. The procedure was initially successful in 79 patients. Ten retinas became detached again after the balloon was withdrawn and required a more permanent buckle. ...

Journal: :Applied ergonomics 2011
A M Dale A E Rohn A Patton J Standeven B Evanoff

Ergonomic studies often use worker estimated hand force reproduced on a dynamometer to quantify force exposures but this method has not been well-studied in real work settings. This study evaluated the validity of worker estimates of hand force in a field study and determined the misclassification of worker estimated hand force exposures compared to directly measured forces. Eight experienced s...

2008
Jennifer E. Michaels

Several different strategies are being considered for ultrasonic structural health monitoring systems using a variety of approaches. Guided wave techniques for interrogating large plate-like structures have probably generated the most interest; these methods have the potential of monitoring large areas with a low sensor density while remaining sensitive to defects. The acousto-ultrasonic nondes...

2008
A. R. Kephart

Accelerated testing in environments aggressive for the specific material have shown that fastener threads that are rolled after strengthening heat treatments have improved resistance to SCC initiation. For example, intergranular SCC was produced in one day when machined (cut) threads of high strength steel (ASTM A193 B-7 and A354 Grade 8) were exposed to an aggressive aqueous environment contai...

نمودار تعداد نتایج جستجو در هر سال