نتایج جستجو برای: femoral stem anteversion

تعداد نتایج: 316465  

Journal: :The Journal of arthroplasty 2006
Shunsaku Nishihara Nobuhiko Sugano Takashi Nishii Hidenobu Miki Nobuo Nakamura Hideki Yoshikawa

We evaluated the effects of conventional hand rasping and robotic milling on the clinical and radiographic results of cementless total hip arthroplasty, with the same computed tomography (CT)-based 3-dimensional preoperative planning using a ROBODOC workstation (Integrated Surgical Systems, Davis, Calif). The robotic milling group consisted of 78 hips, and the hand-rasping group 78 hips. The ra...

Journal: :The Journal of bone and joint surgery. British volume 1986
J H Lau J C Parker L C Hsu J C Leong

A retrospective study was made of the results of surgical treatment of subluxation or dislocation of the hip in patients who had suffered from poliomyelitis. Good results were achieved in 46% and satisfactory results in 24%. The key factors for success are muscle balance, the femoral neck-shaft and anteversion angles, and the acetabular geometry. Iliopsoas transfer can augment the hip abductor ...

Journal: :The Journal of bone and joint surgery. British volume 2007
X Flecher S Parratte J-M Aubaniac J-N Argenson

A clinical and radiological study was conducted on 97 total hip replacements performed for congenital hip dislocation in 79 patients between 1989 and 1998 using a three-dimensional custom-made cementless stem. The mean age at operation was 48 years (17 to 72) and the mean follow-up was for 123 months (83 to 182). According to the Crowe classification, there were 37 class I, 28 class II, 13 clas...

2015
Shinya Hayashi Takaaki Fujishiro Shingo Hashimoto Noriyuki Kanzaki Ryosuke Kuroda Masahiro Kurosaka

BACKGROUND Minimally invasive surgical approaches are widely used for total hip arthroplasty (THA). However, potential problems related to a reduced visual field during surgery, such as implant malposition, neurovascular injury, and poor implant fixation, have been reported. In these situations, a shorter stem is easier to insert in the femoral canal. To evaluate the accuracy of shorter stem or...

Journal: :The Journal of Bone and Joint Surgery. British volume 1962

2005
L. BERMAN R. MITCHELL

A method ofmeasuring femoral neck anteversion using a static B scanner has been described (Moulton and Upadhyay 1982). This study used dried femora in a waterbath and the results obtained were confirmed by direct measurement. Although the experimental scans were performed under direct vision it was assumed that the method would be accurate in vivo where similar images can only be obtained using...

2012
Shigeo Fukunishi Tomokazu Fukui Shoji Nishio Yuki Fujihara Shohei Okahisa Shinichi Yoshiya

In total hip arthroplasty (THA), combined anteversion (CA), the sum of cup anteversion (AV) and stem antetorsion (AT) are used as parameters to assess the appropriateness of overall prosthetic alignment. In this study, we evaluated the CA value based on the post-operative computed tomography (CT) measurements in our patient population who underwent THA using the OrthoPilot™ image-free navigatio...

2016
Wei-Nan Zeng Fu-You Wang Cheng Chen Ying Zhang Xiao-Yuan Gong Kai Zhou Zhi Chen Duan Wang Zong-Ke Zhou Liu Yang

The cause of hip osteoarthritis (OA) remains unclear, morphologic abnormality of hip was thought to be a contributing factor to hip OA. The hypothesis was that there were subtle anatomical morphology differences of the hip between normal and OA subjects; the objective of this study was to explore these anatomical differences which are predisposing to hip OA based on CT 3D reconstruction. Ninety...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید