نتایج جستجو برای: flattening filter

تعداد نتایج: 127226  

Asra Sadat Talebi Majid Jadidi Payman Hejazi Raheb Ghorbani

Medical linear accelerators are one of the most widespread methods for cancer treatment. Despite their advantages, unwanted photoneutrons are produced by high energy linacs. This photoneutrons are as undesired doses to patients and a significant problem for radiation protection of the staffs and patients. Photoneutrons radiological risk must be evaluated because of their high LET and range.in o...

2015
Jin‐Beom Chung Jae‐Sung Kim Keun‐Yong Eom In‐Ah Kim Sang‐Won Kang Jeong‐Woo Lee Jin‐Young Kim Tae‐Suk Suh

The purpose of this study is to investigate the feasibility of using a flattening filter-free (FFF) beam with an endorectal balloon for stereotactic ablative body radiotherapy (SABR) of clinically localized prostate cancer. We assessed plans of SABR with volumetric-modulated arc therapy (VMAT) that used a flattening filter (FF) beam and an FFF beam and compared the verification results of dosim...

2014
Ryan D. Foster Michael P. Speiser Timothy D. Solberg

Linacs equipped with flattening filter-free (FFF) megavoltage photon beams are now commercially available. However, the commissioning of FFF beams poses challenges that are not shared with traditional flattened megavoltage X-ray beams. The planning system must model a beam that is peaked in the center and has an energy spectrum that is softer than the flattened beam. Removing the flattening fil...

2014
Pichandi Anchineyan Ganesh K. Mani Jerrin Amalraj Balaji Karthik Surega Anbumani

Aim. To evaluate the dosimetric benefits of flattening filter-free (FFF) photon beams in intensity modulated radiation therapy (IMRT) and Rapid Arc (RA) over conventional CSI methods. Methods and Materials. Five patients treated with IMRT using static multileaf collimators (MLC) were randomly selected for this retrospective study. Dynamic MLC IMRT, RA, and conformal therapy (3DCRT) were iterate...

Journal: :International journal of radiation research 2021

Analyzing the performance of URT treatment planning system and URT-Linac 506C for flattening filter (FF) free (FFF) photon beams Monte Carlo algorithm by use AAPM TG 119 test cases

2017
Travis J. McCaw Min‐Sig Hwang Si Young Jang M. Saiful Huq

This work quantified differences between recommendations of the TG-51 and TG-51 addendum reference dosimetry protocols. Reference dosimetry was performed for flattened photon beams with nominal energies of 6, 10, 15, and 23 MV, as well as flattening-filter free (FFF) beam energies of 6 and 10 MV, following the recommendations of both the TG-51 and TG-51 addendum protocols using both a Farmer® i...

Journal: :Physics in medicine and biology 2006
Oleg N Vassiliev Uwe Titt Falk Pönisch Stephen F Kry Radhe Mohan Michael T Gillin

Basic dosimetric properties of 6 MV and 18 MV photon beams from a Varian Clinac 21EX accelerator operating without the flattening filter have been measured. These include dose rate data, depth dose dependencies and lateral profiles in a water phantom, total scatter factors and transmission factors of a multileaf collimator. The data are reviewed and compared with measurements for the flattened ...

Journal: :Nihon Hoshasen Gijutsu Gakkai zasshi 2006
Masanori Yamada Hideki Inakoshi Takahide Hayakawa Tomio Inoue Toshifumi Kasahara Satoshi Igarashi

To more easily estimate accurate values of collimator scatter facor, S(c), we suggest a two-component saturation model that accounts for scatter from the primary collimator and flattening filter and from the collimator jaws. This model, which assumes an exponential distribution of scatter intensity, was tested by in-air measurements using a mini-phantom for 4 MV and 10 MV X-rays of a Clinac 210...