نتایج جستجو برای: fluxgate gradiometer survey

تعداد نتایج: 372369  

Journal: :AIP Advances 2023

The measurement accuracy of a magnetic gradiometer relies on magnetometer consistency, accuracy, and assembly technology. traditional methods calibrate error, misalignment the interference field independently. However, after long time work, calibration parameters will inevitably change. Furthermore, it waste lot manpower material resources if is disassembled calibrated step by step. Given above...

1999
Fritz Primdahl

The current-output fluxgate may be tuned by using a serial capacitor. Such tuning increases the sensor sensitivity in the situation when the pick-up coil has a low number of turns. We achieved a signal/feedthrough ratio improvement by a factor of 5. The measured parameters fit the simplified theoretical model within 20% deviation

1999
Pavel Ripka Fritz Primdahl

The current-output fluxgate may be tuned by using a serial capacitor. Such tuning increases the sensor sensitivity in the situation when the pick-up coil has low number of turns. We achieved a signal/feedthrough ratio improvement by a factor of 5. The measured parameters fit the simplified theoretical model within 20% deviation

2015
Chih-Cheng Lu Jeff Huang

A new class of tri-axial miniature magnetometer consisting of a planar fluxgate structure with an orthogonal ferromagnetic fluxguide centrally situated over the magnetic cores is presented. The magnetic sensor possesses a cruciform ferromagnetic core placed diagonally upon the square excitation coil under which two pairs of pick-up coils for in-plane field detection are allocated. Effective pri...

Journal: :Sensors and Actuators A: Physical 2012

2005
Andrea Milani Alessandro Rossi Daniela Villani

We have defined new algorithms for the data processing of a satellite geodesy mission with gradiometer (such as the next European mission GOCE) to extract the information on the gravity field coefficients with a realistic estimate of their accuracy. The large scale data processing can be managed by a multistage decomposition. First the spacecraft position is determined, i.e., a kinematic method...

Journal: :IEICE Transactions 2005
Yong-Ho Lee Hyukchan Kwon Jin-Mok Kim Kiwoong Kim In-Seon Kim Yong-Ki Park

Multichannel superconducting quantum interference device (SQUID) systems based on double relaxation oscillation SQUIDs (DROS) were developed for measuring magnetocardiography (MCG) and magnetoencephalography (MEG) signals. Since DROS provides large fluxto-voltage transfer coefficients, about 10 times larger than the DC SQUIDs, direct readout of the SQUID output was possible using compact roomte...

Journal: :Symmetry 2015
Antonio Palacios Visarath In Patrick Longhini

A large class of dynamic sensors have nonlinear input-output characteristics, often corresponding to a bistable potential energy function that controls the evolution of the sensor dynamics. These sensors include magnetic field sensors, e.g., the simple fluxgate magnetometer and the superconducting quantum interference device (SQUID), ferroelectric sensors and mechanical sensors, e.g., acoustic ...

1998
R. C. Elphic

The FAST magnetic field investigation incorporates a tri-axial fluxgate magnetometer for DC and low-frequency (ULF) magnetic field measurements, and an orthogonal three-axis searchcoil system for measurement of structures and waves corresponding to ELF and VLF frequencies. One searchcoil sensor is sampled up to 2 MHz to capture the magnetic component of auroral kilometric radiation (AKR). Becau...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید