نتایج جستجو برای: gafchromic xrct

تعداد نتایج: 399  

Journal: :basic and clinical cancer research 0
narges jooladi tehran university of medical sciences, tehran, iran seyed rabee mahdavi iran university of medical sciences, tehran, iran hasanali nedaei shahid beheshti university of medical sciences, tehran, iran hasan nosrati shahid beheshti university of medical sciences, tehran, iran mansour naderi tehran university of medical sciences, tehran, iran mahbod esfehani tehran university of medical sciences, tehran, iran

background : this study was set to determine the optimal technique of breast cancer with supraclavicular fossa irradiation. methods : three techniques was compared in this study. techniques were two point symmetric (2p-sym), two point asymmetric (2p-asym) and single point (sp). in 2p-sym all of beams were symmetric, in 2p-asym tangential beams were symmetric and supra was asymmetric, in sp all ...

2007
Robert Y.L. Chu Tin Lam Yongguang Liang

The location and field size of the incident X-ray beam in panoramic dental radiography cannot be ascertained visually most of the time. However, these parameters are needed for quality control and dosimetry determination. To alleviate this problem, we tested GafChromic XR-QA film on two panoramic systems. For each system, we used the length of a cross-sectional image of the incident beam and th...

Journal: :journal of biomedical physics and engineering 0
n singh n k painuly l n chaudhari a chairmadurai t verma d shrotiya

aims: the aim of the present work is (1) to evaluate dose calculation accuracy of two commonly used algorithms for 15 mv small photon fields in a medium encompassing heterogeneity and (2) compare these results with measured results obtained using gafchromic film ebt2. materials and methods: authors employed kailwood (pinus wallichiana) to mimic lung. briefly, seven kailwood plates, each measuri...

Journal: :Medical physics 2007
Alexandra Rink I Alex Vitkin David A Jaffray

The response of radiochromic film, GafChromic EBT, was investigated for dependence on x-ray beam energy using a previously reported real-time optical readout approach. X-ray beams of energy from 75 kVp to 18 MV were employed. The dose-induced change in optical density for the EBT film was compared to values obtained for GafChromic HS and MD-55 films, exposed under the same conditions. All respo...

Journal: :Journal of cancer research and therapeutics 2013
Allahverdi Mahmoud Nourollahi Somayeh Esfahani Mahbod Aghili Mehdi Changizi Vahid Geraily Ghazale

AIM Complex geometry of breast tissue causes perturbation in dose distribution. This problem can beget overdose or under-dose points in match region of three fields. The aim of this study is to create dose homogeneity distribution in match region between tangential and supraclavicular fields (SCF) with Gafchromic external beam therapy (EBT) film. MATERIALS AND METHODS In this study, an anatom...

A. Jabbary Arfaee, A.S. Meigooni, E. Rajab Bolookat, H.A. Nedaie, H.R. Mirzaei, R. Jaberi, S. Gholami, S. Rabi Mahdavi,

Background: One major challenge in brachytherapy is to verify the accuracy of dose distributions calculated by the treatment planning system. In this project, a new phantom design has been introduced for quality assurance of dose distributions in gynocological (GYN) brachytherapy implants using EBT GafChromic film. Materials and Methods: This phantom has been designed and fabricated from 90 sla...

2015
Hong-Wei Liu James Gräfe Rao Khan Ivo Olivotto J Eduardo Villarreal Barajas

PURPOSE To evaluate the role of in vivo dosimetry with radiochromic films for dose verification in cutaneous radiation therapy (RT). METHODS Five patients with 8 cutaneous or sub-cutaneous malignancies of the face, neck, trunk and extremity receiving RT were included. Orthovoltage, megavoltage photon therapies were applied based on anatomic location. The delivered dose for each target was mea...

Journal: :IOP Conference Series: Materials Science and Engineering 2021

Abstract The scope of this work is to assess the influence porosity on mechanical behaviour L-PBF Inconel 718. To end, some test specimens were manufactured by L-PBF, according ASTM E8/E8M. Afterwards, these scanned means XRCT in order analyse each one. geometry generated previous step used for FEM analysis. Finally, results obtained analysis correlated with experimental results, highlighting p...

H.A. Nedaie, Kh. Asnaashari, M. Allahverdi, M. Yarahmadi, O.A. Sauer,

Background: Small photon fields are increasingly used in modern radiotherapy especially in intensity modulated radiation therapy (IMRT) and stereotactic radiosurgery (SRS) treatments. Accurate beam profile and central axis depth doses measurements of such beams are complicated due to the electron disequilibrium. Hence the EBT2 (external beam therapy) Gafchromic film was used for dosimetry of sm...

2008
L. Wang P. Pratt S. D. Felicelli H. El Kadiri J. T. Berry P. T. Wang M. F. Horstemeyer

Pore formation remains a concern in the area of rapid manufacturing by the Laser Engineered Net Shaping (LENS) process. Results usually conflict on the origin of these pores; whether it should stem from an effect due to the physical/mechanical properties of the material or from an effect purely related to the processing parameters. We investigated this problem spanning a range of process parame...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید