نتایج جستجو برای: gas insulated lines gil
تعداد نتایج: 461469 فیلتر نتایج به سال:
Chemical by product diagnostic technique is an efficient, cost-effective and reliable diagnostic technique for gas insulate switchgear condition monitoring in view of its high sensitivity and antiinternal and external electromagnetic interference and noise. In this research paper, coaxial simulated gas insulated switchgear chamber and four different types of artificial defect were designed to c...
This study presents the manner in which transient modeling concepts, which are fully analyzed in the referred standards, are implemented, for the purpose of evaluating the Transient Ground Potential Rise (TGPR). This is a phenomenon of 10–100kV voltages with up to 10µs duration on the grounded enclosure of Gas Insulated Substations (GIS), which may cause concern for personnel safety and pro...
With the increasing demand for precise condition monitoring and diagnosis of 11 gas-insulated switchgears (GIS), it has become a challenge to improve the detection sensitivity of 12 partial discharge (PD) induced in the GIS spacer. This paper deals with the elimination of the 13 capacitive component from the phase resolved partial discharge (PRPD) signal generated in GIS 14 spacer based on the ...
With the growth of world’s population and faster-developing industries, larger amounts electric energy are needed [...]
The housing of zinc oxide lightning arresters are playing major role for discharging the lightning surges. Previously porcelain and silicon rubber housings were mainly used depending on the atmospheric conditions but in practice a lot of problems are faced with these housing. Hence this paper presenting the ZnO blocks performance characterizes with different dielectrics such as air, transformer...
BACKGROUND AND PURPOSE Recent reports describe a high rate of thromboembolic events related to Guglielmi detachable coil (GDC) use in the treatment of cerebral aneurysms. The purpose of this study was to investigate electrolysis-related changes of blood as a potential cause of thromboembolic complications associated with GDC use. METHODS For in vitro observations, 15 GDCs (10 conventional coi...
Since Zwilling and co-workers first introduced the electrochemical anodization method to prepare TiO2 nanotubes in 1999, it has attracted a lot of researches due to its outstanding gas response and selectivity, making it widely used in gas detection field. This review presents an introduction to the sensor applications of TiO2 nanotube arrays (TNTAs) in sulfur hexafluoride (SF6)-insulated equip...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید