نتایج جستجو برای: harmonic distortion

تعداد نتایج: 86870  

2009
R. S. Herrera A. Pérez P. Salmerón J. R. Vázquez S. P. Litrán

Distorted voltage and current waveforms is one of the problems associated to electric power quality. Continuous use of non-linear loads provokes the existence of voltage waveforms with a high distortion. Thus, it is necessary to know the responsible of this problem by means of the commonly named distortion sources identification. In this paper, the problem is analyzed through the harmonic power...

2012
Haroon Farooq Chengke Zhou Mohamed Emad Farrag

Harmonic distortion has garnered a lot of interest in the recent past due to the high advent of the non-linear electronic loads. Moreover, newer technologies including distributed generation and electric vehicles are anticipated to be part of the distribution systems at a mass scale in the near future. This makes it of utmost importance to evaluate the existing power distribution systems and an...

1998
Philip J.A. Ling Cyril J. Eldridge

This paper looks at the evolution and measure of success of different harmonic treatments applied in commercial buildings. Typical levels of voltage distortion are described in light of extensive harmonic data collection at North American sites over several years at hundreds of electrical panels and transformers. The field data shows that contrary to the popular belief, doubling the neutral and...

2012
Parag Nijhawan Ravinder Singh Bhatia Dinesh Kumar Jain

This paper presents the application of DSTATCOM in a distribution network with induction furnace load. Induction furnace is one of the common types of load used in industries like the steel industry. The problem with the induction furnace load is the generation of appreciable amount of harmonic distortion. This distortion results due to the design and operation of the induction furnace. This ha...

2012
C. R. Balamurugan S. P. Natarajan R. Bensraj Naoya Yamashita

Multilevel inverters have become more popular over the years in high power electric applications without use of a transformer and with promise of less disturbance and reduced harmonic distortion. This work proposes three phase five level Diode Clamped Multilevel Inverter (DCMLI) to simulate various modulating techniques for induction motor load. These Pulse Width Modulation (PWM) techniques inc...

1998
Mark F. McGranaghan Dave Mueller

This paper discuses the application of the revised IEEE-519 Harmonics standards to typical industrial facilities employing adjustable speed drives (ASDs). The harmonic generation characteristics of ASDs are described. Requirements for control of the harmonic currents are developed as a function of the ASD characteristics, overall plant loading level, power system characteristics, and power fact...

2014
Sandeep Kumar

The Multilevel Inverter topology is advantageous in high-power and power-quality demanding application without use of transformer with reduced harmonic distortion. This paper explain the basic type of Multilevel Inverter such as diode clamped multilevel inverter (neutral point clamped), flywheel capacitor multilevel inverter (capacitor clamped), cascade multilevel inverter also the modulation a...

Journal: :CoRR 2016
Abhijit Kulkarni Vinod John

Grid-interactive power converters are normally synchronized to the grid using phase-locked loops (PLLs). The performance of the PLLs is affected by the non-ideal conditions in the sensed grid voltage such as harmonics, frequency deviations and dc offsets in single-phase systems. In this paper, a single-phase PLL is presented to mitigate the effects of these non-idealities. This PLL is based on ...

Journal: :IEEE Trans. Industrial Electronics 2000
Chern-Lin Chen Guo-Kiang Horng

A new passive 28-step current shaper for three-phase rectification is proposed in this paper. With a phase-shifting transformer on the ac side and six interphase transformers on the dc side, per-phase input current can be shaped into a 28-step sinusoidal waveform. The total harmonic distortion of ac input currents obtained is 6.54%, lower than one-half of that in a conventional 12-pulse convert...

Journal: :IEEE Trans. Industrial Electronics 2000
Predrag V. Pejovic Zarko Janda

A novel current injection network for low-harmonic rectifiers that apply the third harmonic current injection is proposed in this letter. The current injection network requires one inductor, two capacitors, and one 1 : 1 transformer with voltampere rating of only 0.16% of the input power. The transformer is introduced to provide complete rejection of harmonic components of the injected currents...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید