نتایج جستجو برای: humeral shaft fractures

تعداد نتایج: 70520  

Journal: :Orthopedics 2015
Paul E Matuszewski Tae Won Kim Andre N Gay Samir Mehta

Advances in surgical techniques have increased the role of early surgical intervention for isolated diaphyseal humerus fractures. The goal of this study was to investigate the following: (1) the current trend of operative treatment; (2) factors that affect surgical treatment; and (3) the effect of surgical fixation on length of stay, complication rates, and hospital disposition. The National Tr...

Journal: :Injury 2005
T Apivatthakakul O Arpornchayanon S Bavornratanavech

Minimally Invasive Plate Osteosynthesis (MIPO) has gained popularity with satisfactory clinical outcomes in the treatment of long bone fractures. MIPO for humeral shaft fractures, however, could be a surgically dangerous procedure because of the risk of radial nerve injury. An anatomical study was performed to evaluate the feasibility of MIPO for the humeral shaft fractures, and to study the re...

Journal: :Journal of orthopaedic surgery 2014
M A Fazal Irshad Baloch N Ashwood

PURPOSE. To report the outcomes of Polarus nail fixation for displaced proximal humeral fractures. METHODS. Medical records of 19 men and 27 women aged 26 to 84 (mean, 63) years who underwent fixation using a standard Polarus nail (n=34) or Polarus plus nail with shaft extension (n=12) for proximal humeral fractures of 2 and 3 parts (n=34) and 2-part with extension to the shaft (n=12) were revi...

2011
Marcos Coelho de Azevedo Gualter Maldonado de Azevedo Alexandre Yoshio Hayashi Paulo Emilio Dourado Nascimento

UNLABELLED To evaluate the results obtained from treatment of humeral shaft fractures and their complications using the Osteoline(®) uniplanar external fixator. METHODS The radiographic and functional results from 78 patients with humeral shaft fractures treated using the uniplanar external fixation technique were retrospectively assessed. The patients' ages ranged from 23 to 71 years, with a...

2017

Backgroud: The optimal method of humeral shaft fracture fixation remains in debate. With the dramatic success of intramedullary fixation for fractures of the femur and tibia, there was speculation that IM-ILN might be more appropriate for humeral shaft fractures than DCP. There are very few studies comparing intramedullary interlocking nail and dynamic compression plating in fracture shaft of h...

Journal: :Acta orthopaedica Belgica 2002
F S L Meekers P L O Broos

For many years, plating has proved to be a reliable method for the fixation of fractures of the humeral shaft. In the early nineties however, intramedullary devices became increasingly popular for fractures of the humeral shaft. This was based on a global tendency towards minimally invasive surgery, and the attractiveness of the relatively simple procedure and potentially lower complication rat...

Journal: :Acta orthopaedica Belgica 2006
Cédric Laporte Maurice Thiongo Dominique Jegou

The authors report their experience with the posteromedial surgical approach of the humeral shaft for internal fixation of fractures by plating. Sixteen patients were treated for humeral shaft fractures (14 for recent fractures and two for nonunion) below the mid-diaphysis, all without injury of the radial nerve. Patients were operated in the prone position. Plate and screw fixation on the medi...

Journal: :Injury 2010
Efthimios Papasoulis Georgios I Drosos Athanasios N Ververidis Dionisios-Alexandros Verettas

Functional bracing has been widely accepted as the gold standard for treating humeral shaft fractures conservatively. We conducted a literature review to verify the efficacy of this treatment method. Sixteen case series and two comparative studies fulfilled the criteria set. Analysis of these clinical studies showed that humeral shaft fractures when treated with functional bracing heal in an av...

Journal: :The Journal of bone and joint surgery. British volume 1993
T W Wright G J Miller R A Vander Griend D Wheeler P C Dell

Nine patients with nonunited humeral shaft fractures were treated by open reduction and internal fixation with an intramedullary fibular bone graft and a compression plate. Fixation of the screws was enhanced by passing them through the fibula as well as the two humeral cortices (quadricortical fixation). Eight of the nine fractures united at an average of 3.5 months. Tests on cadaver bones sho...

2013
YuLin Li GuangZhi Ning Qiang Wu QiuLi Wu Yan Li ShiQing Feng

BACKGROUND Radial nerve palsy associated with fractures of the shaft of the humerus is the most common nerve lesion complicating fractures of long bones. However, the management of radial nerve injuries associated with humeral fractures is debatable. There was no consensus between observation and early exploration. METHODS AND FINDINGS The PubMed, Embase, Cochrane Central Register of Controll...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید