نتایج جستجو برای: image noise

تعداد نتایج: 540558  

Journal: :iranian journal of radiology 0
jian hui gu jiangsu province key laboratory of neuroregeneration, nantong university, nantong, jiangsu, china xue jun zhou department of radiology, affiliated hospital of nantong university, nantong, jiangsu, china dong sheng jin department of radiology, jiangsu province official hospital, nanjing, jiangsu, china wen quan ding department of hand surgery, ningbo no.6 hospital, ningbo university, ningbo, zhejiang, china; department of hand surgery, ningbo no.6 hospital, ningbo university, ningbo, zhejiang, china. tel: +86-18106606963 xin wang department of hand surgery, ningbo no.6 hospital, ningbo university, ningbo, zhejiang, china

conclusion vr reconstruction for both single-direction images and sushi using dti25 raw data provides excellent 3d displays of the peripheral nerves in the wrist region. sushi post-processing is a useful denoising tool because it automatically reduces the majority of isotropic object noise. results single-direction vr reconstruction clearly showed the nerves for both dti6 and dti25 but with obv...

Journal: :journal of electrical and computer engineering innovations 2014
mohammad r. pishgoo mohammad r. n. avanaki reza ebrahimpour

optical coherence tomography (oct) uses the spatial and temporal coherence properties of optical waves backscattered from a tissue sample to form an image. an inherent characteristic of coherent imaging is the presence of speckle noise. in this study we use a new ensemble framework which is a combination of several multi-layer perceptron (mlp) neural networks to denoise oct images. the noise is...

A. Amouheidari, A. Jomehzadeh, M. Mohammadi, P. Shokrani,

Background: Electronic portal imaging devices (EPIDs) play an important role in radiation therapy portal imaging, geometric and dosimetric verifications. A successful utilization of EPIDs for imaging and dosimetric purposes requires a reliable quality control process routine to be carried out regularly. In this study, two in-house phantoms were developed and analyzed for implementation in a qua...

Wiener filter suppresses noise efficiently. However, it makes the out image blurred. Curvelet preserves the edges of natural images perfectly, but, it produces visual distortion artifacts and fuzzy edges to the restored image, especially in homogeneous regions of images. In this paper, a new image denoising framework based on Curvelet transform and wiener filter is proposed, which can stop nois...

The sky regions of foggy image processed by all the existing conventional dehazing methods are degraded by color distortion and severe noise. This paper proposes an improved algorithm which combines dark channel prior and inverse image. We first invert the foggy image, and then estimate the transmission of the inverse image. At last, compared with the non-inversed transmission, the larger value...

Ahmad Mostaar, Mohammad Houshyari Zeinab Sattari

Introduction: Polymer gel dosimeters contain chemical materials sensitive to the radiation which are polymerized by the radiation as a function of absorbed dose. So information of spatial dose distribution can be extracted by imaging from irradiated gel. Among imaging techniques, computed tomography (CT) poses as an attractive method because of practical advantages such as acce...

Journal: :iranian journal of basic medical sciences 0
shabnam oloomi department of medical physics, mashhad university of medical science, mashhad, iran hadi noori eskandari department of applied mathematics, school of mathematical sciences, ferdowsi university of mashhad, mashhad, iran seyed rasoul zakavi nuclear medicine research center, imam reza hospital, faculty of medicine, mashhad university of medical sciences, mashhad, iran peter knoll department of nuclear medicine wilhelminenspital vienna, austria faraz kalantari research center for nuclear medicine, tehran university of medical sciences, tehran, iran mohsen hajizadeh saffar department of medical physics, mashhad university of medical science, mashhad, iran

objective(s): in spect, the sinogram contains scatter and lack of attenuated counts that degrade the reconstructed image quality and quantity. many techniques for attenuation and scatter correction have been proposed. an acceptable method of correction is to incorporate effects into an iterative statistical reconstruction. here, we propose new maximum likelihood expectation maximization (mlem) ...

Introduction: The position estimation in gamma detection system will have constant misplacements which can be corrected in the calibration procedure. In the pixelated crystal uniformly irradiation of detector will produce irregular shape due to position estimation errors. This image is called flood field image and is used to calibrate the position estimation. In this work we pr...

Journal: :iranian journal of radiology 0
xianchun zeng department of radiology, guizhou provincial people’s hospital, guiyang, china; department of ct, the first affiliated hospital of kunming medical university, kunming, china shaolei kang department of ct, the first affiliated hospital of kunming medical university, kunming, china rongpin wang department of radiology, guizhou provincial people’s hospital, guiyang, china dan han department of ct, the first affiliated hospital of kunming medical university, kunming, china; department of ct, the first affiliated hospital of kunming medical university, kunming, p. o. box: 650032, china. tel: +86-87165324888, fax: +86-87165324888 yong wang department of ct, the first affiliated hospital of kunming medical university, kunming, china shiping yang department of ct, the first affiliated hospital of kunming medical university, kunming, china

conclusion safire reconstruction provided better coronary image quality and displayed the number, morphology, and surrounding lumen of calcium plaques more accurately than traditional fbp reconstruction, with safire3 achieving the best results. results the subjective ratings of image quality using safire1–safire5 reconstructions were significantly higher than those using fbp, with safire3 achie...

Mahsa Noori-Asl, somayeh Sotoudeh

Introduction: In nuclear medicine imaging, detection of the scattered photons along with the primary photons is one of the major problems that can lead to a decrease in ddiagnostic accuracy. Therefore, use of a suitable scatter correction method can help to improve of the image quality and increase of diagnostic accuracy. The aim of this study is evaluation of five energy wind...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید