Journal: :Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology 2008
Wouter van Elmpt Leah McDermott Sebastiaan Nijsten Markus Wendling Philippe Lambin Ben Mijnheer

Electronic portal imaging devices (EPIDs) have been the preferred tools for verification of patient positioning for radiotherapy in recent decades. Since EPID images contain dose information, many groups have investigated their use for radiotherapy dose measurement. With the introduction of the amorphous-silicon EPIDs, the interest in EPID dosimetry has been accelerated because of the favourabl...

Journal: :Radiation Oncology (London, England) 2009
Giorgia Nicolini Alessandro Clivio Antonella Fogliata Eugenio Vanetti Luca Cozzi

PURPOSE A study was performed comparing dosimetric characteristics of volumetric modulated arcs (RapidArc, RA) and fixed field intensity modulated therapy (IMRT) on patients with bilateral breast carcinoma. MATERIALS AND METHODS Plans for IMRT and RA, were optimised for 10 patients prescribing 50 Gy to the breast (PTVII, 2.0 Gy/fraction) and 60 Gy to the tumour bed (PTVI, 2.4 Gy/fraction). Ob...

Journal: :Annali dell'Istituto superiore di sanita 2009
Clemens Woda Céline Bassinet François Trompier Emanuela Bortolin Sara Della Monaca Paola Fattibene

The increasing risk of a mass casualty scenario following a large scale radiological accident or attack necessitates the development of appropriate dosimetric tools for emergency response. Luminescence dosimetry has been reliably applied for dose reconstruction in contaminated settlements for several decades and recent research into new materials carried close to the human body opens the possib...

2013
Christiane Schuchardt Harshad Kulkarni Carolin Zachert Richard P Baum

Aim: Calculating the absorbed dose is important for the determination of risk and therapeutic benefit of internal radiation therapy. Optimal dose estimations require time-consuming and sophisticated methods, which are difficult due to practical reasons. To make dosimetry available for each of the patients, we developed a specific dosimetry procedure used in daily clinical routine. Materials and...

Journal: : 2023

Dosimetric modeling of radiation transport in skeletal bone tissues using computational phantoms provides the doses internal exposure to active marrow. Computational ICRP are created for reference people with anatomical and physiological characteristics typical an average individual. The calculated such will correspond certain population-average values. Individual variability introduce a stocha...

Journal: :Inhalation toxicology 2001
L M Hanna S R Lou S Su A M Jarabek

In 1994, the U.S. Environmental Protection Agency introduced dosimetry modeling into the methods used to derive an inhalation reference concentration (RfC). The type of dosimetric adjustment factor (DAF) applied had to span the range of physicochemical characteristics of the gases listed on the Clean Air Act Amendments in 1991 as hazardous air pollutants (HAPs) and accommodate differences in av...

2015
Caldas

Onyx samples were studied in this work to verify their dosimetric properties. The Onyx stone is considered nobler than marble. At IPEN, the radiation metrology group has studied new materials for application in highdose dosimetry. The Onyx samples were exposed using a Gamma-Cell 220 system ( 60 Co), for doses of 50 Gy up to 300 kGy. The lower detection doses, the reproducibility of the OSL resp...

2002
Timothy D. Solberg John J. DeMarco Geoffrey Hugo Robert E. Wallace

Monte Carlo calculations and TLD measurements have been performed for the purpose of characterizing dosimetric properties of new commercially available brachytherapy sources. All sources tested consisted of a solid core, upon which a thin layer of 125I has been adsorbed, encased within a titanium housing. The PharmaSeed BT-125 source manufactured by Syncor is available in silver or palladium co...

2012
Krishna Murthy

Purpose: To validate a locally fabricated phantom of Imatrixx-2D Array by comparing its results with ArcCheck phantom and comparing portal dosimetry measurements with the two phantom studies. Materials and Methods: Electronic Portal Imaging Devices and Epiqa software were used for portal dosimetry. An Imatrixx-2D array with a locally fabricated phantom and ArcCheck cylindrical phantom were used...