Purpose Ion beam radiotherapy offers enhances dose conformity to the tumor volume while better sparing healthy tissue compared conventional photon radiotherapy. However, increased gradient also makes it more sensitive uncertainties. While most important uncertainty source is patient itself, delivery subject Most of proton therapy centers used cyclotrons, which deliver typically a stable over ti...
background: a set of hardware stereotactic radiosurgery is designed and constructed. the scope of this article is to describe how we have designed and developed stereotactic collimation assembly for a 9 mv neptun 10 pc linac. materials and methods: one collimator holder and six collimators were made, with their radiation field diameter between 12.5 mm to 25 mm at isocenter level. beam data, suc...
Methods A large gel phantom was used to assess phase offset in through-plane phase contrast images in x (left to right), y (anterior to posterior) and z directions at the isocenter and in positions ±40 mm and ±80 mm away from the isocenter. Repeated measures were averaged and fit to linear regressions. Phase correction was validated in human study for the assessment of aorta and pulmonary arter...
Treatment of Multiple Brain Metastases Using Stereotactic Radiosurgery with Single-Isocenter Volumetric Modulated Arc Therapy: Comparison with Conventional Dynamic Conformal Arc and Static Beam Stereotactic Radiosurgery by
PURPOSE New devices for IMRT and VMAT QA are continually becoming available. Despite the availability of these devices they are underutilized for routine mechanical QA. In this work we take advantage of the cylindrical geometry of the Arc Check phantom to perform tests that are an integral part of commissioning and routine QA. METHODS The Arc Check is a cylindrical phantom with a diameter of ...
Medical linear accelerators are one of the most widespread methods for cancer treatment. Despite their advantages, unwanted photoneutrons are produced by high energy linacs. This photoneutrons are as undesired doses to patients and a significant problem for radiation protection of the staffs and patients. Photoneutrons radiological risk must be evaluated because of their high LET and range.in o...
Machine Performance Check (MPC) is an automated and integrated image-based tool for verification of beam and geometric performance of the TrueBeam linac. The aims of the study were to evaluate the performance of the MPC geometric tests relevant to OBI/CBCT IGRT geometric accuracy. This included evaluation of the MPC isocenter and couch tests. Evaluation was performed by comparing MPC to QA test...
BACKGROUND To assess the accuracy of fractionated stereotactic radiotherapy (FSRT) using a stereotactic mask fixation system. PATIENTS AND METHODS Sixteen patients treated with FSRT were involved in the study. A commercial stereotactic mask fixation system (BrainLAB AG) was used for patient immobilization. Serial CT scans obtained before and during FSRT were used to assess the accuracy of pat...