نتایج جستجو برای: linac head modeling
تعداد نتایج: 557109 فیلتر نتایج به سال:
Introduction: Skin sparing is one of the most desirable characteristics of high energy photon beams. However, the photons emerging from the target of linacs are contaminated by secondary electrons as a result of their interactions with air, collimators, flattening filter and any other objects in their path. This phenomenon tends to increase the skin dose received b...
The aim of this study was to characterize electron contamination a flattened (FF) and an unflattened (FFF) Varian Clinac iX 6X 15X photon beams using Monte Carlo (MC) simulation. EGSnrc MC technique used model the head simulate dose distribution FF FFF beam in water phantom. materials geometrical data linac were provided by Tan Tock Seng Hospital (TTSH) Singapore. modeled removing flattening fi...
Objective: The aim of the present study is to simulate 6 MV and 18 MV photon beam energies of a Siemens Primus Plus medical linear accelerator (Linac) and to verify the simulation by comparing the results with the measured data.Methods: The main components of the head of Siemens Primus Plus linac were simulated using MCNPX Monte Carlo (MC) code. To verify the results, experimental data of perce...
Here, we report on the working group ‘‘Optics and Beam Transport’’ of the 2005 Energy-Recovery-Linac Workshop. This workshop also had working groups on ‘‘Electron Guns and Injector Designs’’, ‘‘Superconducting RF and RF Control’’, and ‘‘Synchronization and Diagnostics/Instrumentation’’. Here, we are concerned with the many different ERL proposals that international laboratories have been workin...
Introduction: The ultimate goal of radiation treatment planning is to yield a high tumor control probability (TCP) with a low normal tissue complication probability (NTCP). Historically dose volume histogram (DVH) with only volumetric dose distribution was utilized as a popular tool for plan evaluation hence present study aimed to compare the radiobiological effectiveness of the cobalt-60 (Co...
Stereotactic radiosurgery is a method for focused irradiation of intracranial lesions. Linac-based radiosurgery is currently performed by two techniques: couch mounted and pedestal mounted. In the first technique a device is required to affix the patient's head to the couch and neoreover to translate it accurately. Structure of such a device constructed by the authors plus acceptance test perfo...
background: stereotactic radiosurgery is an important clinical tool for the treatment of small lesions in the brain, including benign conditions, malignant and localized metastatic tumors. a dosimetry study was performed for elekta ‘synergy s ’ as a dedicated stereotactic radiosurgery unit, capable of generating circular radiation fields with diameters of 1-5 cm at isocentre using the beam/egs4...
background: monte carlo (mc) modeling of a linear accelerator is a prerequisite for monte carlo dose calculations in external beam radiotherapy. in this study, a simple and efficient model was developed for elekta sl-25 linear accelerator using mcnp4c monte carlo code materials and methods: the head of elekta sl-25 linac was simulated for 6 and 18 mv photon beams using mcnp4c mc code. energy sp...
the monte carlo method can be used to describe any technique that approximates solutions to quantitative problems through statistical sampling. this method is considered to be the most accurate method for dose calculation in radiotherapy. for complete modeling of a linear accelerator, it is required that the manufactured information covers all data, but some data such as primary electron energy...
for superficial lesions, the electrons may be used for radiation therapy. the high energy photons and electrons are produced by a linear accelerator (linac). many of electron fields need the shielding of normal or critical organs. the electron shields are usually lead slabs with few millimeter thickness which should be placed near the skin, less than 1 centimeter away from skin. in the inspec...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید