نتایج جستجو برای: liquid membrane electrode

تعداد نتایج: 654404  

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه صنعتی اصفهان - دانشکده شیمی 1390

abstract venlafaxine, 1–[2–(dimethylamino)–1–(4–methoxyphenyl) ethyl]cyclohexanol hydrochloride is a novel non-tricyclic antidepressant. venlafaxine is a second generation antidepressant drug, has a neuropharmacologic profile distinct from that of existing antidepressants including tricyclic compounds, selective serotonin reuptake inhibitors and monoamine oxidase inhibitors. venlafaxine impart...

2012
Chi-Yuan Lee Yu-Ming Lee Shuo-Jen Lee

In this study, local area water content distribution under various gas purging conditions are experimentally analyzed for the first time. The local high frequency resistance (HFR) is measured using novel micro sensors. The results reveal that the liquid water removal rate in a membrane electrode assembly (MEA) is non-uniform. In the under-the-channel area, the removal of liquid water is governe...

Journal: :journal of physical & theoretical chemistry 2015
h. aghaie m. h. felcri m. arvand k. zare m. aghaie

a pvc membrane cr(iii) ion selective electrode has been constructed using 2h-1,4-benzothioazine-2,3(4h)dione dioxime (btd) as membrane carrier. the influence of membrane composition on the electroderesponse was studied. the electrode exhibits a nernstian response over a cr(iii) concentration range of 1.0 x10 6 to 1.0>< 10-1 m (r = 0.99) with a slope of 19.5 ± 0.5 mv per decade of concentration,...

Journal: :journal of physical & theoretical chemistry 2012
m. h. fekri m. darvishpour

a pvc membrane ni(ii) ion selective electrode has been constructed using (1e,2e)-bis(2-aminophenyl)n'1,n'2-dihydroxyethanebis as membrane carrier. the electrode exhibited a goodpotentiometric response for ni(ii) over a wide concentration range 1.0×10-4 to 1.0×10-1m with aslope of 29.4±0.5 mv/decade a and a working ph range of 6.5-9.0. it had a fast response time of≤20s. the best performance was...

Journal: :journal of physical and theoretical chemistry 0
m. h. fekri - m. darvishpour -

a pvc membrane ni(ii) ion selective electrode has been constructed using (1e,2e)-bis(2-aminophenyl)n&apos;1,n&apos;2-dihydroxyethanebis as membrane carrier. the electrode exhibited a goodpotentiometric response for ni(ii) over a wide concentration range 1.0×10-4 to 1.0×10-1m with aslope of 29.4±0.5 mv/decade a and a working ph range of 6.5-9.0. it had a fast response time of≤20s. the best perfo...

Journal: :iranian journal of chemistry and chemical engineering (ijcce) 2012
huang du-shu yi zhong-zhou, huang zhao-long yi ping, li zi-jin

this paper deals with the extraction of l-theanine containing aliquat 336 as a carrier and cyclohexane as solvent across bulk liquid membrane. the optimum operation condition are as follows: extraction time of 150 min, initial concentration of theanine in the feed phase is 1.8 g/l, the carrier concentration is 0.5 m, the ion of the receiving phase is 0.2 m nacl of na2hpo4-nah2po4 buffer solutio...

E. Baghdar M. Darvishpour M.H. Fekri

A poly(vinyl chloride) membrane based on a new a-dioxime derivative as membrane carrier was prepared andinvestigated as a Cr(III) selective electrode. The electrode exhibits a good potentiometric response for Cr(III)over a wide concentration range 1.0 x 10-6 to 1.0 x 10-1 M with a slope 19.5+0.5 mV/decade and low detectionlimit of 8.9 x 10-7 M. It has a fast response time < 15 s. The best perfo...

2004
Qingzhi Guo Ralph E. White

A model for the simulation of the steady-state impedance response of a polymer electrolyte membrane fuel cell ~PEMFC! cathode is presented. The catalyst layer of the electrode is assumed to consist of many flooded spherical agglomerate particles surrounded by a small volume fraction of gas pores. Stefan-Maxwell equations are used to describe the multicomponent gas-phase transport occurring in b...

Journal: :journal of agricultural science and technology 2009
b. mostafaie maynagh b. ghobadian t. tavakkoli hashjin m. r. jahannama

in this study, an electrostatic sprayer which had been previously designed and constructed was evaluated in order to quantify the charging of droplets. liquid atomization was achieved by using an ultrasonic nozzle. the nozzle maximum flow rate was 25 milliliters per minute and vibration frequency was about 30 khz. the induction method was used for charging the output droplets. all experiments w...

Journal: :journal of physical & theoretical chemistry 2007
masoud giahi mohammad ali bagherinia azin azari

sol-gel and polymeric membrane electrodes, based on thiacalix[4]arene as a neutral carrier, weresuccessfully developed for the detection of vo2+ in aqueous solutions. the sol-gel and pvcmembrane electrodes exhibited linear response with nernstian slopes of 29.3 and 28.4 mv perdecade, respectively, within the vanadyl ion concentration ranges from 1.0 × 10-6 to 1.0 × 10-1mol dm-3 and from 1.0 × 1...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید