In this thesis, we develop a motion correction method to overcome the degradation of image quality introduced by respiratory motion in positron emission tomography (PET), so that diagnostic performance for lung cancer can be improved. Lung cancer is currently the most common cause of cancer death both in the UK and in the world. PET/CT, which is a combination of PET and CT, providing clinicians...
This paper presents a study that demonstrates the potential of using finite element (FE) lung model constructed using 4D-MRI (3D + time) for tracking tumor motion during a respiratory cycle. A series of volumetric images of one lung cancer patient was acquired over time under free breathing and sorted into respiratory phases. A FE model of the lung with the tumor was constructed using the volum...
In this paper, we present a real-time simulation and visualization framework that models a deformable surface lung model with tumor, simulates the tumor motion and predicts the amount of radiation doses that would be deposited in the moving lung tumor during the actual delivery of radiation. The model takes as input a subject-specific 4D Computed Tomography (4D CT) of lungs and computes a defor...
For PET/CT, fast CT acquisition time can lead to errors in attenuation correction, particularly at the lung/diaphragm interface. Gated 4D PET can reduce motion artifacts, though residual artifacts may persist depending on the CT dataset used for attenuation correction. We performed phantom studies to evaluate 4D PET images of targets near a density interface using three different methods for at...
Objective To evaluate the technical feasibility of four-dimensional (4D) CT for the functional evaluation of the pediatric diaphragm. Materials and Methods In 22 consecutive children (median age 3.5 months, age range 3 days-3 years), 4D CT was performed to assess diaphragm motion. Diaphragm abnormalities were qualitatively evaluated and diaphragm motion was quantitatively measured on 4D CT. L...
PURPOSE To investigate the correlation of gross tumor volume (GTV) motion with the structure of interest (SOI) motion and volume variation for middle and distal esophageal cancers using four-dimensional computed tomography (4DCT). PATIENTS AND METHODS Thirty-three patients with middle or distal esophageal carcinoma underwent 4DCT simulation scan during free breathing. All image sets were regi...
Studying the complex thorax breathing motion is an important research topic for medical (e.g. fusion of function and anatomy, radiotherapy planning) and engineering (reduction of motion artifacts) questions. In this paper we present first results on studying the 4D motion of segmented lung surfaces from CT scans at several different breathing states. For this registration task we extend the sha...
Introduction: In radiotherapy with external surrogates, exact information of tumor position is one of the key factors that improves treatment delivery. Many dynamic tumors in thorax region of patient move mainly due to respiration and are known as intra-fractional motion error that must be compensated, as well. One of clinical strategy is using Stereotactic Body Radiation Thera...
Studying the complex thorax breathing motion is an important research topic for medical (e.g. fusion of function and anatomy, radiotherapy planning) and engineering (reduction of motion artifacts) questions. In this paper we present first results on investigating the 4D motion of segmented lung surfaces from CT scans at several different breathing states. For this registration task we extend th...