نتایج جستجو برای: microtensile bond strength

تعداد نتایج: 267833  

2013
Daniel Galafassi Vivian Colucci Doglas Cecchin Camila Scatena Telma N. Nascimento Silmara A. M. Corona

OBJECTIVE The bond strength of adhesives in irrigated dentin behaves differently over time. The aim of this study was to evaluate the influence of long-term water storage and thermocycling on the microtensile bond strength of adhesive systems to dentin irrigated with endodontic solutions. MATERIALS AND METHODS Sixty human molars were used after removal of the occlusal portion and exposure of ...

Journal: :journal of dental research, dental clinics, dental prospects 0
mahmoud bahari faculty of dentistry, tabriz university of medical sciences siavash savadi oskoee soodabeh kimyai firoz pouralibaba marouf norouzi farrokh farhadi

background and aims. the aim was to evaluate the effect of casein phosphopeptide–amorphous calcium phosphate (cpp-acp) on microtensile bond strength (µtbs) to carious affected dentin (cad) using etch-and-rinse and self-etch adhesive systems. materials and methods. the occlusal surface of 32 human molars with moderate occlusal caries was removed. infected dentin was removed until reaching cad an...

Journal: :Journal of dentistry 2010
Andrea Fabianelli Sarah Pollington Federica Papacchini Cecilia Goracci Amerigo Cantoro Marco Ferrari Richard van Noort

OBJECTIVES The aim of this study was to evaluate the effect of different surface treatments on the microtensile bond strength between a leucite reinforced glass-ceramic and composite resin. METHODS Leucite reinforced ceramic blocks (n=24) were constructed using the hot pressing technique. The blocks were assigned to 4 groups, which received the following surface treatments: G1: hydrofluoric (...

Journal: :Dental materials : official publication of the Academy of Dental Materials 2007
Alessandra R Peris Fabio H O Mitsui Maristela M Lobo Ana K B Bedran-russo Giselle M Marchi

OBJECTIVES The present study evaluated the microtensile bond strength and caries formation on adhesive/dentin interfaces before and after dynamic chemical formation of secondary caries. METHODS Restorations were prepared on the dentin surface of 80 bovine incisors using four adhesive systems: two fluoride-free (Single Bond and Clearfil SE Bond) and two fluoride containing (Optibond Solo Plus ...

2017
Bruna Gabrielle da Silva Sutil Alexandre Henrique Susin

OBJECTIVES To evaluate the effects of dentin pretreatment and temperature on the bond strength of a universal adhesive system to dentin. MATERIAL AND METHODS Ninety-six extracted non-carious human third molars were randomly divided into 12 groups (n=8) according to Scotchbond Universal Adhesive (SbU) applied in self-etch (SE) and etch-and-rinse (ER) mode, adhesive temperature (20°C or 37°C) a...

Journal: :American journal of dentistry 2010
Ali I Abdalla

PURPOSE To evaluate the effect of water storage on the microtensile dentin bond strength of one total-etch and four self-etching adhesives to dentin. METHODS The adhesive materials were: one total-etch adhesive (Admira Bond) and four self-etch adhesives (Clearfil S tri Bond, Hybrid Bond, Futurabond NR, Adhe SE). Freshly extracted human third molar teeth were used. For each tooth, dentin was e...

Journal: :The journal of contemporary dental practice 2013
Maneesha Das G Anil Kumar Sindhu Ramesh Surendranath Garapati Deepak Sharma

BACKGROUND Smear layer is a negative factor which prevents adhesion of the filling material to the dentinal walls. Recent advances in dental research have incorporated lasers as a potential adjunct in root canal treatment by removing the smear layer before filling the root canal system, enhancing the adhesion of sealers to dentin and improving the sealing ability. AIM To evaluate the microten...

Amir Ghasemi, Leila Eftekhar, Majid Bargrizan, Marzieh Gholami, Mohammad Asnaashari, Yasaman Rezvani,

Background and Aim: Er,Cr:YSGG laser irradiation has been suggested as an effective method of cavity preparation and surface treatment to enhance the bond strength. The aim of this study was to assess the microshear bond strength of Fuji II LC glass ionomer (GI) cement to primary dentin following bur preparation and Er,Cr:YSGG irradiation. Materials and Methods: This in vitro, experimental stu...

2017
Farnoosh Fallahzadeh Shadab Safarzadeh-Khosroshahi Mohammad Atai

BACKGROUND The study aims to investigate the effect of incorporation of sepiolite nanoparticles on the microtensile bond strength of an experimental dentin bonding to the human dentin. MATERIAL AND METHODS The sepiolite nanoparticles were incorporated into an experimental methacrylate-based dentin bonding system in concentrations of 0.0, 0.2, 1.0, 2.0, and 5.0 weight percents. The specimens w...

Journal: :Dental materials journal 2012
Kohyoh Soeno Yohsuke Taira Shuichi Ito

An experimental conditioner (Exp), which was an aqueous solution of 10% ascorbic acid and 5% ferric chloride, was prepared in this study. This study evaluated the effect of Exp on the microtensile bond strength between a self-curing resin and dentin after long-term water immersion. Flat human dentin surfaces were sequentially pretreated with 40% phosphoric acid, 10% sodium hypochlorite, and Exp...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید