نتایج جستجو برای: mv photon beam

تعداد نتایج: 199565  

Journal: :iranian journal of medical physics 0
fatemeh seif department of medical physics & khansari hospital, arak university of medical sciences, arak, iran mojtaba karbalayi department of medical physics, faculty of medicine, isfahan university of medical sciences, isfahan, iran. mohamad reza bayatiani department of medical physics & khansari hospital, arak university of medical sciences, arak, iran mitra karbalayi department of medical physics, faculty of medicine, iran university of medical sciences, tehran, iran. mohamad javad tahmasebi-birgani department of medical physics & golestan hospital, medical faculty, ahvaz jundishapur university of medical sciences, ahvaz, iran

introduction for dose measurement in megavoltage (mv) photon beams with ion chambers, the effect of volume occupied by the air cavity is not negligible. therefore, the result of measurement should be corrected with a displacement perturbation correction factor (pdis) or using an effective point of measurement (epom). the aim of this study is to calculate the epom for cylindrical ion chamber and...

Introduction: MRI-only treatment planning (TP) can be advantageous in paediatric radiotherapy. However, electron density extraction is necessary for dose calculation. Normally, after bone segmentation, a bulk density is assigned. However, the variation of bone bulk density in patients makes the creation of pseudo CTs challenging. This study aims to assess the effects of bone den...

2009
Christopher F Njeh Timothy W Raines Mark W Saunders

Highly attenuating radiation treatment couches are no longer useful in the present era of radiotherapy utilizing IMRT and IGRT. Carbon fibers couch tops with its high tensile strength and low density present a useful alternative. The objective of the current study was to quantify the attenuation of megavoltage photons through a Brainlab imaging couch top and headrest at various angles and field...

2015
Ying Zhang Yuanming Feng Munir Ahmad Xin Ming Li Zhou Jun Deng Qinghui Zhang

The goal of this study is to evaluate the effects of intermediate megavoltage (3-MV) photon beams on SBRT lung cancer treatments. To start with, a 3-MV virtual beam was commissioned on a commercial treatment planning system based on Monte Carlo simulations. Three optimized plans (6-MV, 3-MV and dual energy of 3- and 6-MV) were generated for 31 lung cancer patients with identical beam configurat...

Introduction For dose measurement in Megavoltage (MV) photon beams with ion chambers, the effect of volume occupied by the air cavity is not negligible. Therefore, the result of measurement should be corrected with a displacement perturbation correction factor (Pdis) or using an effective point of measurement (EPOM). The aim of this study is to calculate the EPOM for cylindrical ion chamber and...

M. Allahverdi, M. Hoseini-Ghahfarokhi, M. Shahriari, M. Zabihzadeh, M.R. Ay, S.R. Mahdavi,

Background: During intensity modulated radiation therapy (IMRT) technique, theoretically, presence of flattening filter (FF) across the beamline of clinical linear accelerator (linac) is not essential to obtain uniform lateral profiles due to intensity modulation of photon beams by multileaf collimators (MLCs). The aim of this study was to investigate the dosimetrical properties of 18 MV photon...

Abbas Haghparast Elnaz Balvasi, Peyman Hejazi,

Introduction: Radiotherapy is one of the effective methods in the treatment of cancer. In the recent methods of radiotherapy, intensity modulated radiotherapy (IMRT) technique by compensators is used. when photon beam passes the compensator, scattered photons can be generated within the compensator. The presence of scattered photons may complicate the design of compensators as...

Journal: :journal of biomedical physics and engineering 0
s a rahimi tarbiat modares university b hashemi tarbiat modares university s r mahdavi iran university of medical sciences

background: estimating dosimetric parameters for small fields under non-reference conditions leads to significant errors if done based on conventional protocols used for large fields in reference conditions. hence, further correction factors have been introduced to take into account the influence of spectral quality changes when various detectors are used in non-reference conditions at differen...

Mansour Zabihzadeh Mohammad Reza Ay, Mojtaba Hoseini- Ghahfarokhi Seyed Rabee Mahdavi

Introduction: During intensity modulated radiation therapy (IMRT) technique, theoretically, presence of flattening filter (FF) across the beamline of clinical linear accelerator (linac) is not essential to obtain uniform lateral profiles due to intensity modulation of photon beams by multileaf collimators (MLCs). The aim of this study was to investigate the dosimetrical propert...

ژورنال: سنجش و ایمنی پرتو 2020

Radiotherapy using linear accelerators is known as an effective modality for cancer treatment. The photons energy of treatment beams significantly affect the dose distribution. Therefore, it is important to accurately evaluate the photon energy spectra. In this study, MCNPX Monte Carlo code (version 2.6.0) was used to simulate an 18 MV photon beam of a Varian 2100C/D linear accelerator. By matc...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید