نتایج جستجو برای: oscillometric blood pressure
تعداد نتایج: 963715 فیلتر نتایج به سال:
BACKGROUND Accurate blood pressure (BP) measurement depends on the reliability of oscillometric cuff pressure pulses (OscP) and Korotkoff sounds (KorS) for automated oscillometric and manual techniques. It has been widely accepted that respiration is one of the main factors affecting BP measurement. However, little is known about how respiration affects the signals from which BP measurement is ...
The technique of non-invasive blood pressure monitoring was used to compare the 24-hr control of blood pressure in 10 patients with essential hypertension taking either twice daily propranolol or a once daily long-acting formulation of propranolol (propranolol LA). Both drug regimes produced smooth control of blood pressure and heart rate through the 24 hours and significantly reduced blood pre...
This study aims to validate blood pressure (BP) values measured by an oscillometric BP monitor and seek possible calibration methods if discrepancies exist. Noninvasive BP measurement outcomes were determined using an oscillometric BP monitor (Omron HBP-1300) versus a mercury sphygmomanometer (standard device). Two percent of subjects enrolled in an epidemiological investigation were systematic...
This study sought to determine whether patient characteristics such as age, sex, blood pressure, and pulse pressure differently affect the accuracy of an oscillometric (SpaceLabs 90207) and a microphonic (TM2420 version 7) blood pressure monitor. Blood pressure recorded by two oscillometric and two microphonic ambulatory monitors was compared with simultaneous readings by two pairs of trained, ...
We present a novel approach to improve the estimation of systolic (SBP) and diastolic blood pressure (DBP) from oscillometric waveform data using variable characteristic ratios between SBP and DBP with mean arterial pressure (MAP). This was verified in 25 healthy subjects, aged 28 ± 5 years. The multiple linear regression (MLR) and support vector regression (SVR) models were used to examine the...
The technique of non-invasive blood pressure monitoring was used to compare the 24-hr control of blood pressure in 10 patients with essential hypertension taking either twice daily propranolol or a once daily long-acting formulation of propranolol (propranolol LA). Both drug regimes produced smooth control of blood pressure and heart rate through the 24 hours and significantly reduced blood pre...
The purpose of this study was to evaluate a partially automated sphygmomanometer for accuracy in the ambulatory care setting. Patients seen in 80 consecutive office visits served as subjects. Blood pressures were measured simultaneously under standard conditions. The oscillometric test instrument and a standard mercury manometer were connected with a Y tube. Paired t-tests were used to determin...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید