نتایج جستجو برای: pencil beam

تعداد نتایج: 116960  

Journal: :iranian journal of radiation research 0
s.b. jia department of physics , ferdowsi university of mashhad, mashhad, iran a.a. mowlavi department of physics , hakim sabzevari university, sabzevar, iran m.h. hadizadeh department of physics , ferdowsi university of mashhad, mashhad, iran m. ebrahimi loushab department of physics , ferdowsi university of mashhad, mashhad, iran

background: the advantages of proton beam in radiation therapy- like small lateral scattering as well as absence of exit dose tail in the organs which are after the tumor- make it capable of delivering more treatment doses to the target and much lesser to the critical tissues near it. materials and methods: in this study, the monte carlo mcnpx code has been used to simulate a slab head phantom ...

2010
M. Hedjazi Moghari D. C. Peters J. Smink L. Goepfert K. V. Kissinger B. Goddu T. H. Hauser M. E. Josephson W. J. Manning R. Nezafat

Introduction: High spatial resolution left atrial (LA) late gadolinium enhancement (LGE) is acquired during free-breathing with 2D pencil-beam right hemidiaphragm (RHD) respiratory navigator (NAV). A NAV restore pulse with larger diameter is usually applied after the inversion pulse of the LGE sequence to restore the magnetization of the RHD [1]. This NAV restore pulse also re-inverts the pulmo...

Journal: :Physics in medicine and biology 2015
Jerimy C Polf Stephen Avery Dennis S Mackin Sam Beddar

The purpose of this paper is to evaluate the ability of a prototype Compton camera (CC) to measure prompt gamma rays (PG) emitted during delivery of clinical proton pencil beams for prompt gamma imaging (PGI) as a means of providing in vivo verification of the delivered proton radiotherapy beams. A water phantom was irradiated with clinical 114 MeV and 150 MeV proton pencil beams. Up to 500 cGy...

Journal: :journal of biomedical physics and engineering 0
sh keshazare kn toosi university of technology s f masoudi kn toosi university of technology f s rasouli kn toosi university of technology

background: recent studies in eye plaque brachytherapy have shown a considerable difference between the dosimetric results using water phantom and a model of human eye containing realistic materials. in spite of this fact, there is a lack of simulation studies based on such a model in proton therapy literatures. in the presented work, the effect of utilizing an eye model with ocular media on pr...

Journal: :Journal of radiology and imaging 2023

Purposes: We perform further development for our previous Gaussian-pencil-beam-model used calculating the electron dose in water under clinical electron-beam irradiation. The main purpose is to evaluate accurately parallel beam depth-doses at deep depths beyond about extrapolated range (Rp) an infinite field. Methods: Sets of field were reconstructed beams E=6, 12, and 18 MeV light Monte Carlo ...

2008
Christophe Caloz

Some recent advances done by the author and his collaborators in the field of antennas and antenna arrays are presented. These include: multiband systems, an infinite-wavelength antenna array series feeding network, a true time delay system allowing beam squint free scanning, a pencil-beam full-space scanning array, a beam-forming system based on active aperture discretization, a MIMO dynamic r...

A.A. Mowlavi, M. Ebrahimi Loushab, M.H. Hadizadeh, S.B. Jia,

Background: The advantages of proton beam in radiation therapy- like small lateral scattering as well as absence of exit dose tail in the organs which are after the tumor- make it capable of delivering more treatment doses to the target and much lesser to the critical tissues near it. Materials and Methods: In this study, the Monte Carlo MCNPX code has been used to simulate a slab head phantom ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید