BACKGROUND The Humphrey field analyser (HFA), Humphrey-Zeiss frequency doubling perimeter, and the Medmont automated perimeter (MAP) are three commonly used automated perimeters with threshold achromatic methodologies. Visual field loss may be detected earlier with strategies that target cell lines with reduced redundancy or which suffer selective damage. METHOD To compare these three perimet...
PURPOSE We compared patterns of visual field loss detected by standard automated perimetry (SAP) to saccadic vector optokinetic perimetry (SVOP) and examined patient perceptions of each test. METHODS A cross-sectional study was done of 58 healthy subjects and 103 with glaucoma who were tested using SAP and two versions of SVOP (v1 and v2). Visual fields from both devices were categorized by m...
The aim of this study was to evaluate the role of Humphrey Matrix perimetry to better guide appropriate referral of at-risk individuals for glaucoma assessment. Fifty-two consecutive patients referred to a specialist glaucoma ophthalmology practice for an opinion about a new diagnosis of glaucoma were enrolled. Prior to assessment for presence of open-angle glaucoma, patients performed Humphrey...
Background: Motion detection perimetry and frequency doubling perimetry are methods that have been developed with the goal of detecting glaucomatous field defects earlier than conventional white-on-white perimetry. It is well recognized that the development of cataract and pupillary constriction can significantly influence perimetric thresholds when screening for, or following the progression o...
PURPOSE Standard automated perimetry (SAP) shows a marked increase in variability in damaged areas of the visual field. This study was conducted to test the hypothesis that larger stimuli are associated with more uniform variability, by investigating the retest variability of four perimetry tests: standard automated perimetry size III (SAP III), with the SITA standard strategy; SAP size V (SAP ...
Microperimetry, also referred to as fundus perimetry or fundus-driven perimetry, enables simultaneous acquisition of visual sensitivity and eye movement data. We present sensitivity data collected from 60 participants with normal vision using gaze-contingent perimetry. A custom designed spatially dense test grid was used to collect data across the visual field within 13° of fixation. These data...
BACKGROUND The purpose of this study was to test the effect of ethyl alcohol on the koniocellular and magnocellular pathway of visual function and to investigate the relationship between such visual field changes and retrobulbar blood flow in healthy subjects. METHODS In 12 healthy subjects (mean age 32 ± 4 years), color Doppler imaging, short-wavelength automated perimetry, and frequency dou...
PURPOSE To compare sensitivity and specificity of achromatic perimetry with size I stimulus (WW-I) with standard automated perimetry (SITA strategy) and blue on yellow perimetry (SWAP) for early diagnosis of glaucoma. METHODS Seventy-three eyes of 73 suspects, glaucomatous and normal subjects underwent automated perimetry with SITA 24-2, WW-I and SWAP. After application of specific criteria o...
Visual field extent along the four diagonal meridia was measured cross-sectionally in 180 normal children (infants and toddlers), and 22 adults. Infants were tested monocularly at 3.5, 7, or 9 months, and toddlers were tested binocularly at 11, 17, or 30 months. Adult control data were obtained under monocular viewing. Three testing methods were investigated: static and hybrid static-kinetic pe...
An attempt was made to correlate various types of visual field defects on automated perimetry with the findings of computed tomography in 44 patients of supratentorial tumors. All the patients above the age of 10 years were subjected to complete neurological examination including investigations like plain X-rays and CT scan, however, MRI and angiography were performed wherever indicated. Ocular...