Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2009
Tohru Shiga Yuichi Morimoto Naoki Kubo Norio Katoh Chietsugu Katoh Wataru Takeuchi Reiko Usui Kenji Hirata Shinichi Kojima Kikuo Umegaki Hiroki Shirato Nagara Tamaki

UNLABELLED An autoradiography method revealed intratumoral inhomogeneity in various solid tumors. It is becoming increasingly important to estimate intratumoral inhomogeneity. However, with low spatial resolution and high scatter noise, it is difficult to detect intratumoral inhomogeneity in clinical settings. We developed a new PET system with CdTe semiconductor detectors to provide images wit...

2017
Cong Zhao Xi Chen Luo Ouyang Jing Wang Mingwu Jin

Scatter contamination is one of the main sources of decreasing the image quality in cone-beam computed tomography (CBCT). The moving blocker method is economic and effective for scatter correction (SC), which can simultaneously estimate scatter and reconstruct the complete volume within the field of view (FOV) from a single CBCT scan. However, at the regions with large intensity transition in t...

2001
Habib Zaidi

Received 12/27/2000; revised 2/26/2001; accepted 3/14/2001. For correspondence or reprints contact: Habib Zaidi, Ph.D., Division of Nuclear Medicine, Geneva University Hospital, CH-1211 Geneva, Switzerland. Tel: 41 22 372 72 58, Fax: 41 22 372 71 69, E-mail: [email protected] A new method to assess the scatter component in positron emission tomography (PET) based on estimating the low-freque...

Journal: :Physics in medicine and biology 2005
Jay Wu Keh-Shih Chuang Ching-Han Hsu Meei-Ling Jan Ing-Ming Hwang Tzong-Jer Chen

Fully three-dimensional (3D) positron emission tomography (PET) can achieve high sensitivity of coincidence events, but the absence of inter-slice septa inevitably leads to increased scattered events. The scattered events can represent as much as 50% of the total detected events. In this research, we proposed a scatter correction method for 3D PET based on beam stoppers and dual-energy window a...

2016
Mukesh N. Meshram Srimanta Pramanik C.P. Ranjith Saravana K. Gopal Rishabh Dobhal

This study presents the basic dosimetric properties of photon beams of a Versa HD linear accelerator (linac), which is capable of delivering flattening filter-free (FFF) beams with a beam quality equivalent to the corresponding flattened beams based on comprehensive beam data measurement. The analyzed data included the PDDs, profiles, penumbra, out-of-field doses, surface doses, output factors,...

Journal: :Medical physics 1997
M S Westmore A Fenster I A Cunningham

A new special-purpose computed tomographic (CT) imaging system is described which produces images based on measurements of the low-angle (0-10 degrees) x-ray diffraction properties of an object. Low-angle scatter in the diagnostic x-ray energy range is dominated by coherent scatter, and the system uses first-generation CT geometry to acquire a diffraction pattern for each pencil beam. The patte...

2010
Oliver Díaz Mary Yip Jorge Cabello David R. Dance Kenneth C. Young Kevin Wells

This paper reports on a further development of an image simulation chain, and in particular, the inclusion of contrast degradation across an image using scatter to primary ratios calculated using Monte Carlo simulation. The Monte Carlo technique, using the Geant4 toolkit, has been implemented to model the scatter conditions when imaging the CDMAM phantom with commercial digital mammography. Obs...

2006
Bassel Kassas Firas Mourtada John L. Horton Richard G. Lane Thomas A. Buchholz Eric A. Strom

A recently introduced brachytherapy system for partial breast irradiation, MammoSite, consists of a balloon applicator filled with contrast solution and a catheter for insertion of an 192Ir high-dose-rate (HDR) source. In using this system, the treatment dose is typically prescribed to be delivered 1 cm from the balloon's surface. Most treatment-planning systems currently in use for brachythera...

Journal: :Radiological physics and technology 2012
Masayoshi Mizuta Shigeru Sanada Hiroyuki Akazawa Toshifumi Kasai Shuji Abe Yasuhiro Ikeno Shigeki Mitou

Our purpose in this study was to establish a selection standard for anti-scatter grids for a direct conversion flat-panel detector (FPD) system. As indices for grid evaluation, we calculated the selectivity, Bucky factor, and the signal-to-noise ratio improvement factor (SIF) by measuring rates of scatter transmission, primary transmission, and total transmission (based on the digitally display...

Journal: :Journal of nuclear medicine technology 2008
Faraz Kalantari Hossein Rajabi Nahid Yaghoobi

UNLABELLED A poor signal-to-noise ratio attributable to a low injected dose of thallium and the presence of scattered photons are the major impediments in the use of thallium as an imaging agent. Thallium decays in a complicated way and emits photons in a wide range of energies (68-82 keV). To increase the ratios of primary photons to scatter photons (primary-to-scatter ratios) and possibly inc...