نتایج جستجو برای: pre ionization

تعداد نتایج: 349227  

Journal: :iranian journal of radiation research 0
m.a. gadhi bahawalpur institute of nuclear medicine and oncology (bino) bahawalpur, pakistan s.a. buzdar department of physics, the islamia university of bahawalpur, pakistan m. afzal department of physics, the islamia university of bahawalpur, pakistan sh. fatmi bahawalpur institute of nuclear medicine and oncology (bino) bahawalpur, pakistan m.s. akhtar bahawalpur institute of nuclear medicine and oncology (bino) bahawalpur, pakistan a.h. nizamani department of physics, university of sind, jamshoro, hyderabad, pakistan

background: the effectiveness and safety of brachytherapy treatment is mainly concerned with the calibration of sources and their traceability to internationally accepted standards. secondary standard dosimetry laboratory (ssdl) does not offer calibration of ionization chambers with gamma-ray spectrum of high dose rate source 192ir . this work has been carried out to calibrate the high dose rat...

1999
S. Adamenko

A hypothesis of the beam auto–focusing in the relativistic vacuum diode with a needle anode is proposed. A physical model of the effect is elaborated. As is shown, auto –focusing of high current beam can be caused by ions emitting from the anode. Initial (pre focusing) stage of focusing is provided with ionization of the gas molecules absorbed in the anode surface. Then (at quasi–steady stage),...

Journal: :iranian journal of radiation research 0
s. abdollahi reza radiotherapy oncology center, mashhad, iran m. mohammadi department of medical physics, hamadan university of medical science, hamadan, iran a. ebrahimzadeh pezeshki reza radiotherapy oncology center, mashhad, iran z. alizadeh reza radiotherapy oncology center, mashhad, iran

background: in order to deliver the precise dose to the target in radiotherapy, absorbed dose to water at the reference point should be assessed. when the calibration procedure is performed for a reference dosimeter in the 60co beam of a secondary standard dosimetry laboratory (ssdl), the total uncertainty in absorbed dose to water (dw) is estimated to be approximately 1.5%. this study attempts...

Journal: :Journal of water and health 2013
Chang-Hua Chen Li-Chen Lin Yu-Jun Chang Chun-Eng Liu Maw-Soan Soon Ching-Shan Huang

The purpose of this study was to identify the prevalence of fungal colonization in water systems and to evaluate the effect of decreasing fungal colonization by a copper-silver ionization system. Environmental samples were collected for fungal culture prospectively during a 1-year period (2011-2012) at the study hospital. A total of 392 water samples were examined from five buildings on March 1...

Journal: :Analytical biochemistry 2013
David Bonnel Julien Franck Céline Mériaux Michel Salzet Isabelle Fournier

In the current study, we compared plastic matrix-assisted laser desorption/ionization (MALDI) plates pre-spotted with different solid ionic matrices. Data reflect that after 3 months of storage, the standards were oxidized in α-cyano-4-hydroxycinnamic acid (HCCA) whether or not in HCCA/3-acetylpyridine (3APY) and HCCA/aniline, and certain peptides, such as ubiquitin, were not detected using the...

Journal: :iranian journal of science and technology (sciences) 2005
y. k agrawal

calix(6)arene hydroxamic acids (iii) are synthesised for the first time by reactingcalix(6)arene acid chloride(ii) with substituted hydroxylamines at low temperature in the presence ofsodium bicarbonate. the p-carboxycalix(6)arene(i) is obtained by an acid catalysed condensationreaction of p-hydroxybenzoic acid and formaldehyde. these calixarenes are characterised by meltingpoint, uv, ir, 1h nm...

Journal: :iranian journal of science and technology (sciences) 2008
m. r eskandari

the ionization effects of charged particles produced in neutron interactions for boron neutroncapture therapy are considered here using srim monte carlo code. the estimated values of these effects ina plexiglas acrylic phantom are shown to agree well with the available experimental values in high boronconcentration areas. as expected, the ionization effects from lithium and alpha particles are ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید