نتایج جستجو برای: rebar fracture
تعداد نتایج: 95629 فیلتر نتایج به سال:
Reinforced concrete is the most commonly used material in construction industry. However, one disadvantage of reinforced that environmental factors cause materials to penetrate and steel bar corrosion. Rebar corrosion increases its volume significantly by approximately 3–6 times, which lowers concrete–rebar adhesion. This severely affects serviceability durability structures. The economic socia...
To explore the feasibility of improving the delivery process of reinforced concrete, we focus in this paper on reinforcing bars (rebar) used in cast-in-place (CIP) concrete. Specifically, we describe the methodology for set-based design of rebar that we are pursuing in an ongoing research effort. Set-based design makes it possible to maintain feasible solutions for longer in the design process ...
Borated water leakage through spent fuel pools (SFPs) at pressurized water reactors is a concern because it could cause corrosion of reinforcement steel in the concrete structure and compromise the integrity of the structure. Because corrosion rate of carbon steel in concrete in the presence of boric acid is lacking in published literature and available data are equivocal on the effect of boric...
In order to assess the bond behavior of deformed steel rebars in recycled-aggregate concrete (RAC) incorporating both fine and coarse recycled aggregate, pull-out tests were carried out in this study on 16-mm diameter deformed steel rebars embedded concentrically in RAC. The concrete was designed using equivalently mixed proportions of both recycled coarse aggregate and recycled fine aggregate....
This study investigated the response of reinforced concrete (RC) slabs in building structures to internal explosions. The performances of two slabs designed in accordance with the protective structural design and conventional gravity design approaches were evaluated in terms of midspan displacements, support rotations, and damage patterns. Data from available slab blast experiments in the open ...
Senior Associate Vice President for Research Executive Director, Discovery Park Purdue University Hovde Hall, Room 332 610 Purdue Mall West Lafayette, IN 47907-2040 [email protected] Rose E. Raskin, DVM, PhD, Diplomate ACVP Professor of Veterinary Clinical Pathology Dept of Veterinary Pathobiology Purdue University School of Veterinary Medicine 725 Harrison Street West Lafayette, IN 47907 rraski...
In this paper, a novel kind of method to monitor corrosion expansion of steel rebars in steel reinforced concrete structures named fiber optic coil winding method is proposed, discussed and tested. It is based on the fiber optical Brillouin sensing technique. Firstly, a strain calibration experiment is designed and conducted to obtain the strain coefficient of single mode fiber optics. Results ...
workers who carry out manual rebar tying tasks are exposed to muscular-skeletal injuries associated with the use of manual tools and the movements associated with them (force, repetitiveness and awkward wrist postures). this paper presents a background on musculoskeletal injuries directly linked to manual and mechanical rebar tying method is conducted. the objective of this study is to compare ...
This paper explores a set of new equations to predict the bond strength between fiber reinforced polymer (FRP) rebar and concrete. The proposed equations are based on a comprehensive statistical analysis and existing experimental results in the literature. Namely, the most effective parameters on bond behavior of FRP concrete were first identified by applying a factorial analysis on a part of t...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید