نتایج جستجو برای: secondary posterior chamber intraocular lens
تعداد نتایج: 506269 فیلتر نتایج به سال:
The case for capsular bag fixation of the Sinsky-Kratz type of posterior chamber intraocular implant lens is presented, and the various methods in use to position implant lenses are outlined. The new forceps are described and the rationale for their adoption and use is given in an illustrated, step-by-step fashion. Their additional use in anterior chamber intraocular lens implantation is mentio...
purpose: to compare the effect of implantation of a single-piece hydrophilic foldable acrylic intraocular lens (iol) with rectangular optic edge and a single-piece polymethyl methacrylate (pmma) iol with rounded optic edges on posterior capsular opacification )pco(. methods: this randomized clinical trial study comprised 74 eyes with senile cataract in an otherwise normal eye in patients older ...
Here, we report on a patient with pseudoexfoliation syndrome who developed acute angle-closure glaucoma with a marked myopic shift due to anterior dislocation of the posterior chamber intraocular lens almost 16 months after an uneventful phacoemulsification. Examination with a Scheimpflug camera was extremely useful in confirming the diagnosis. This is the fist case of late-onset angle-closure ...
purpose : to evaluate intraocular pressure (iop) and anterior chamber depth (acd) change after phacoemulsification with posterior chamber intraocular lens implantation methods : in this quasi-experimental study, 84 patients with senile cataract were included. all patients had normal iop. patients with traumatic and complicated cataract, any history of uveitis, glaucoma, or other ocular disease ...
MATERIAL AND METHODS Retrospective 5-year study based on general and ophthalmic history records, and including 268 eyes (174 patients), aged 50 years and over. Ophthalmological examination involved visual acuity, measuring of intraocular pressure, slit lamp examination and indirect ophthalmoscopy. Type of surgical treatment was tailored for each patient (extra capsular cataract extraction, phac...
OBJECTIVE To compare the retrobulbar anesthesia and intracameral anesthesia using preservative-free bupivacaine hydrochloride 0.5% in terms of effectiveness, complications and comfort to the patient during phacoemulsification with posterior chamber intraocular lens implantation. METHODS This was a hospital based comparative study of two methods of anesthesia, conducted at LRBT Free Eye and Ca...
A 44-year-old man with anterior megalophthalmos arrived at the clinic presenting a cataract in the right eye. The corneal diameter was 13 mm. Iridodonesis and phacodonesis were evident during slit lamp examination. Anterior chamber depth was 5.89 mm, and the diameter of the capsular bag was approximately 14.45 mm. Due to the large capsular bag, a standard posterior chamber intraocular lens was ...
Penetrating ocular trauma is one of the most important causes of vision loss, especially in men, and can be associated with intraocular foreign bodies. The incidence of intraocular cilia after trauma is very low. Here we report the case of a 24-year-old man who visited Poostchi Ophthalmology Clinic (Shiraz, Iran) due to a gradual vision loss in his left eye over the past 2 months. The probable ...
BACKGROUND This study evaluates patients with congenital aniridia and cataract who underwent phacoemulsification, capsular tension ring placement, and foldable intraocular lens implantation. METHODS In this prospective case series, 10 patients (17 eyes) underwent cataract surgery via a 3.2 mm clear corneal incision. A continuous circular capsulorhexis with <6 mm diameter was employed. A capsu...
The capsule of the crystalline lens, if sufficiently present, is used as a support tissue for intraocular lens (IOL) implantation surgery performed on vitrectomized eyes. Eye trauma or iatrogenic damage during complicated cataract surgery, loss of position and zonule connections of the crystalline lens, and IOL via dislocation may cause loss of support tissue for lens capsule implantation prior...