نتایج جستجو برای: seismic isolation methods
تعداد نتایج: 2018772 فیلتر نتایج به سال:
A simplified method for the seismic design of low-rise, base-isolated shear wall structures is proposed in MOC-2012. This simplified method is basically a hybrid method, where the design of the isolation system is a simpler version for the static method available in US guidelines for the design of base-isolated structures and the design of the superstructure essentially is an improved version o...
Seismic hazards remained as a challenge to engineers over ages. In order to reduce loss of life and damage to property due to earthquake, several techniques have been developed among which Seismic Isolation technique using Elastomeric Isolators has gained high acceptance and becoming popular all over the world, due to its simplicity, reliability and overall cost effectiveness. Seismic Isolation...
The goals of this project are to develop rehabilitation strategies and enhance seismic design guidelines for key equipments in power substations, which are one of the most critical facilities in a power system. Furthermore, it will provide the knowledge base to be integrated into the overall loss estimation model for the entire power network. To achieve these goals, key substation equipments ar...
The base isolation systems are among the passive control devices that have been used over the last three decades to limit the seismic-induced response of structures. In this regard, the Uniform Building Code provisions (UBC) has incorporated a special section for the seismic design of base isolated structures since its 1991 edition. Due to the importance of the behavior of these structures unde...
The base isolation systems are among the passive control devices that have been used over the last three decades to limit the seismic-induced response of structures. In this regard, the Uniform Building Code provisions (UBC) has incorporated a special section for the seismic design of base isolated structures since its 1991 edition. Due to the importance of the behavior of these structures unde...
The seismic response of bridges seismically isolated by lead-rubber bearings (LRB) to earthquake excitations of different magnitudes is presented in this thesis. The force-deformation behavior of LRB is considered as bilinear. The specific purpose of the study is to assess the effect of seismic isolation on the peak response of bridges subjected to different base accelerations ranging from 0.05...
The paper presents the world state-of-the-art of the Nuclear Power Plants (NPPs) provided with seismic isolation and focuses on the main problems related to the application of this technology to so peculiar structures, characterized by high masses, large sizes and severe safety requirements due to the possibility of relevant accidents with release of radioactivity and other extremely dangerous ...
The article presents the main provisions of modeling multi-story buildings with seismic isolation, characteristics isolation device, structural elements and materials, methodology for conducting experimental studies on a laboratory vibro-stand under dynamic (seismic) effects results modeling.
the base isolation systems are among the passive control devices that have been used over the last three decades to limit the seismic-induced response of structures. in this regard, the uniform building code provisions (ubc) has incorporated a special section for the seismic design of base isolated structures since its 1991 edition. due to the importance of the behavior of these structures unde...
Computer-aided fault imaging and interpretation is a fundamental tool for subsurface structure characterization and modeling, and the existing methods are primarily based on seismic discontinuity analysis (e.g., coherence and semblance) that evaluates the lateral variation of waveform and/or amplitude. However, such attributes have a limited resolution on subtle faults without apparent displace...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید