Journal: :International journal of medical physics, clinical engineering and radiation oncology 2017
Chengyu Shi Brian Wang

The purpose of this study is to investigate the potential use of Ir-192 as the source for real time imaging during HDR (High Dose Rate) brachytherapy treatment. Phantom measurement was performed to determine outside of the body dose. Monte Carlo code, EGSnrcMP egs_inprz, was used for the simulation to calculate the outside of the body x-ray signal for CT reconstruction. Matlab code was develope...

Introduction: An operational computed tomography (CT) scanner is a major source of human exposure to ionizing radiation. Exposure increases the risk of cancer and aplastic anaemia. All radiation exposures should be justified and optimized to meet the clinical objective. In order to avoid the administration of excessive radiation dose to patients, diagnostic reference l...

Background: Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk-free. CT is a device with higher patient dose in comparison with other conventional radiation procedures. Objective: This study is aimed at evaluating radiation dose to patients from ...

2017
Dongwen Zhang Aixia Xu

The objective of the present study was to evaluate the application of dual-source CT perfusion imaging and MRI for the diagnosis of primary liver cancer. Sixty-three patients with primary liver cancer were selected between February 2015 and May 2016. All patients underwent examinations by dual-source CT perfusion imaging and MRI. The perfusion parameters of the focus center and normal liver par...

2013
Tom van Seeters Geert Jan Biessels Joris M. Niesten Irene C. van der Schaaf Jan Willem Dankbaar Alexander D. Horsch Willem P. T. M. Mali L. Jaap Kappelle Yolanda van der Graaf Birgitta K. Velthuis

BACKGROUND AND PURPOSE Good reliability of methods to assess the extent of ischemia in acute stroke is important for implementation in clinical practice, especially between observers with varying experience. Our aim was to determine inter- and intra-observer reliability of the 1/3 middle cerebral artery (MCA) rule and the Alberta Stroke Program Early CT Score (ASPECTS) for different CT modaliti...

Alireza Karimian, Arman Rahmim Mehdi Nasri Nasrabadi, Nematollah Ahmadi

Introduction: The CT machine utilizes a bowtie filter to shape the X-ray beam and remove lower energy photons. Configuration of this bowtie filter is complex and its geometry is often not available in detail. It causes the CT dose index (CTDI) be with the different values in measurement versus Monte Carlo simulation studies and other analytical calculations. It is important esp...

Journal: :International Journal of Biomedical Imaging 2009
Deepak Bharkhada Hengyong Yu Hong Liu Robert J. Plemmons Ge Wang

Current computed tomography (CT) scanners, including micro-CT scanners, utilize a point x-ray source. As we target higher and higher spatial resolutions, the reduced x-ray focal spot size limits the temporal and contrast resolutions achievable. To overcome this limitation, in this paper we propose to use a line-shaped x-ray source so that many more photons can be generated, given a data acquisi...

Journal: :Medical physics 2008
Martin J Murphy Zhouping Wei Mirek Fatyga Jeffrey Williamson Mitchell Anscher Timothy Wallace Elizabeth Weiss

PURPOSE To measure the sensitivity of deformable image registration to image noise. Deformable image registration can be used to map organ contours and other treatment planning data from one CT to another. These CT studies can be acquired with either conventional fan-beam CT systems or more novel cone-beam CT techniques. However, cone-beam CT images can have higher noise levels than fan-beam CT...