نتایج جستجو برای: spect

تعداد نتایج: 10967  

Journal: :Revista espanola de medicina nuclear e imagen molecular 2012
B Volkan-Salanci E Lay Ergün Ç Genc Sel D Yalnizoğlu G Turanli

Moyamoya disease (MMD) is a cerebrovascular disorder involving stenosis of brain vessels. Brain perfusion SPECT in MMD demonstrates impaired perfusion in ischemic areas. We present a 6-year-old boy with MMD. The patient had numbness on the right arm and simultaneous electroencephalography changes while studying arms up on the table. To differentiate seizure and ischemic symptoms, brain perfusio...

1995
Yong Zhang Jeffrey A. Fessler Neal H. Clinthorne W. Leslie Rogers

Single Photon Emission Computed Tomographic im-ages(SPECT) have relatively poor resolution. In an attempt to improve SPECT image quality, many methods have been developed for including anatomic information, extracted from higher resolution, structurally correlated Magnetic Resonance images(MRI), into SPECT reconstruction process. These methods provide improved SPECT reconstruction accuracy if t...

2011
Sita Jayalakshmi Pushpalatha Sudhakar Manas Panigrahi

Molecular imaging with ictal single photon emission computed tomography (SPECT) is an established functional imaging modality for the presurgical evaluation of patients with refractory partial onset seizures. SPECT coregistered on to the MRI has greater sensitivity to identify the ictal onset zone. Ictal SPECT should always be interpreted in the context of other presurgical investigations. Icta...

Journal: :Current Pharmaceutical Design 2021

Monte Carlo algorithms have a growing impact on nuclear medicine reconstruction processes. One of the main limitations myocardial perfusion imaging (MPI) is effective mitigation scattering component, which particularly challenging in Single Photon Emission Computed Tomography (SPECT). In SPECT, no timing information can be retrieved to locate primary source photons. methods allow an event-by-ev...

Objective(s): This study sought to determine the diagnostic yield of SPECT/CT in localizing axillary sentinel lymph nodes (SLNs) in early breast cancer patients where planar scintigraphy (PS) was equivocal or negative.Methods: Prospective analysis of early stage breast cancer patients with nonpalpable axillary nodes undergoing SLN localization prior to nodal sampling for axillary staging. PS fi...

2013
Gurunanthan Palani Aarthee S. Karthikeyan Jacobsen Gordon Karthik Ananthasubramaniam

Purpose: Regadenoson (REG) is currently becoming the stress agent of choice in patients undergoing pharmacologic single photon emission computed tomography (SPECT). However, in patients with left bundle branch block (LBBB) and ventricular paced rhythm (VPR), hesitation exists amongst clinicians to use REG-SPECT due to the concern that the increased heart rate could cause false positive SPECT re...

Journal: :Physics in medicine and biology 2013
Xiao Deng Jean-François Beaudoin Jules Cadorette Charles Naaman Roger Lecomte Rutao Yao

We developed SPECT imaging capability on an animal PET scanner to provide a cost effective option for animal SPECT imaging. The SPECT add-on sub-system was enabled by mechanically integrating a multiple-pinhole collimator in the PET detector ring. This study introduces a method to calibrate the geometrical parameters of the SPECT add-on using the PET imaging capability of the scanner. The propo...

Journal: :Journal of nuclear medicine technology 2000
M W Groch W D Erwin

OBJECTIVE SPECT has become a routine procedure in most nuclear medicine departments. SPECT provides significant technical challenges for the nuclear medicine technologist, as compared with planar imaging, in the areas of SPECT acquisition, image reconstruction, and data processing. Many new advances in SPECT methodology are becoming available, such as iterative reconstruction, multimodality fus...

Journal: :Circulation. Cardiovascular imaging 2011
Alessia Gimelli Matteo Bottai Assuero Giorgetti Dario Genovesi Annette Kusch Andrea Ripoli Paolo Marzullo

BACKGROUND A novel technology has been developed for ultrafast (UF) single-photon emission CT (SPECT) myocardial perfusion imaging by using a pinhole collimation design and multiple cadmium zinc telluride crystal arrays. The purpose of this study was to compare myocardial perfusion imaging obtained by UF-SPECT with standard (S) SPECT in patients with known or suspected coronary artery disease. ...

Journal: :Physics in medicine and biology 2003
C Grova P Jannin A Biraben I Buvat H Benali A M Bernard J M Scarabin B Gibaud

Quantitative evaluation of brain MRI/SPECT fusion methods for normal and in particular pathological datasets is difficult, due to the frequent lack of relevant ground truth. We propose a methodology to generate MRI and SPECT datasets dedicated to the evaluation of MRI/SPECT fusion methods and illustrate the method when dealing with ictal SPECT. The method consists in generating normal or pathol...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید