نتایج جستجو برای: thorax phantom

تعداد نتایج: 24331  

Journal: :International journal of cancer management 2021

Background: Despite the benefits of contrast-enhanced computed tomography (CT) scans in better tumor volume delineation, it can affect accuracy dose calculation radiation therapy. This study examined this effect on a thorax phantom. Objectives: The influence different variables including concentrations Visipaque contrast media, sizes, and CT scan energies measurement was examined. Methods: Tran...

Journal: :Physics in medicine and biology 1997
Z Liang J Cheng J Ye

In order to model photon attenuation and detector resolution variation as a depth-dependent convolution for efficient reconstruction of quantitative SPECT, a central-ray approximation is necessary. This work investigates the impact of the approximation upon reconstruction accuracy and computational efficiency. A patient chest CT image was acquired and converted into an object-specific attenuati...

2013
Martin Burger Jahn Müller Sabrina Dill

Positron Emission Tomography is an important functional imaging technique in nuclear medicine, where the measured data are corrupted by Poisson noise. Hence, this thesis begins with an overview on PET and the introduction of a mathematical and statistically motivated model in order to deal with the emerging inverse problem. At this point numerical methods like regularization are required for im...

Journal: :Radiation protection dosimetry 2016
Bharti Kataria Michael Sandborg Jonas Nilsson Althén

Automatic exposure control (AEC) in computed tomography (CT) facilitates optimisation of dose absorbed by the patient. The use of AEC requires appropriate 'patient centring' within the gantry, since positioning the patient off-centre may affect both image quality and absorbed dose. The aim of this experimental study was to measure the variation in organ and abdominal surface dose during CT exam...

Journal: :Physics in medicine and biology 2008
S Shcherbinin A Celler T Belhocine R Vanderwerf A Driedger

The goal of this study was to determine the quantitative accuracy of our OSEM-APDI reconstruction method based on SPECT/CT imaging for Tc-99m, In-111, I-123, and I-131 isotopes. Phantom studies were performed on a SPECT/low-dose multislice CT system (Infinia-Hawkeye-4 slice, GE Healthcare) using clinical acquisition protocols. Two radioactive sources were centrally and peripherally placed insid...

2004
Stanislaw Szpala Marcin Wierzbicki Gerard Guiraudon Terry Peters

While most currently available minimally invasive robotically assisted cardiac surgical systems do not employ 3D image guidance, such support can be generated using pre operative images such as CT. Previously we demonstrated a virtual model of the thorax with simulated surgical instruments, and a pulsating virtual model of the coronary arteries. In this paper we report the overlay of optical en...

2016
Jean‐Pierre Mege Sun Wenzhao Attila Veres Guillaume Auzac Ibrahima Diallo Dimitri Lefkopoulos

The purpose of this investigation was to evaluate the dose on megavoltage CT (MVCT) images required for tomotherapy. As imaging possibilities are often used before each treatment and usually used several times before the session, we tried to evaluate the dose delivered during the procedure. For each scanning mode (fine, normal, and coarse), we first established the relative variation of these d...

موحد, منصور, حکمت, سپیده, شرفی, علی‌اکبر, مرتضی‌زاده, توحید,

    Background: In this survey the absorbed dose by kidneys, bladder, liver and ovaries with 99mTc-EC (99mTc Ethylene dicysteine) renal scintigraphy was measured and compared with the absorbed dose from 99mTc-DTPA (99mTc - Dietheylne Triamine Penta-Acid), which often is used in renal scintigraphy.Methods: In this applicable study, we used a water phantom with geometrical sizes similar to that o...

سدادی, فریبا, فروزانی, قاسم, محمدرضایی, ماهان, کریمیان, علیرضا,

In nuclear medicine, studies of important tissues such as cardiac, the emitted photons from the cardiac before reaching the gamma detectors are attenuated and scattered by other tissues inside the thorax. Therefore, the quality and contrast of the image will be reduced. In this research, to improve the quality of cardiac images by SPECT system, the most convenient algorithms for attenuation cor...

نمودار تعداد نتایج جستجو در هر سال